1005196 is listed in the Safety Relays range at ChipApex. The manufacturer field lists Mayser. Its product description is Control Unit SG-EFS 104/2W. Review the specifications below when checking this part for your BOM.
Safety Relays specifications for 1005196
- Description:Control Unit SG-EFS 104/2W
- Series:SG-EFS
- Mfr:Mayser
- Package:Bulk
- Mounting Type:DIN Rail
- Coil Voltage:24VAC/DC
- Contact Form:SPST-NO (1 Form A)
- Contact Rating (Current):4:00 AM
- Switching Voltage:250VAC, 24VDC - Max
- Features:Diode, Lighted Indicator, Resistor
- Termination Style:Screw Terminal
- Must Operate Voltage:-
- Must Release Voltage:-
- Operate Time:50 ms
- Release Time:15 ms
- Operating Temperature:-25°C ~ 55°C
- Contact Material:-
Safety Relays datasheet and documents for 1005196
Safety Relays Overview
The Mayser SG-EFS 104/2ZK is a safety control unit designed for the monitoring of protective edges and light curtains on industrial doors. It integrates two independent evaluation channels to ensure high reliability in safety applications. The device processes signals from connected sensors, such as edge sensors or light barriers, and triggers appropriate safety responses when an obstacle is detected. It supports various switching outputs to control door operators and includes diagnostic features to monitor system integrity.
Safety Relays Feature Summary
- Dual-channel evaluation architecture for enhanced safety integrity
- Integrated diagnostic capabilities for continuous system monitoring
- Compatibility with standard industrial protective edge sensors
- Direct interface capability for controlling door drive mechanisms
Safety Relays Applications
- Monitoring protective edges on sliding industrial doors
- Safety integration for lifting garage doors
- Control unit for automated warehouse access gates
- Protection monitoring for rolling shutter systems
Safety Relays Procurement Notes
Verify that the specific order number matches the required configuration, particularly regarding the number of evaluation channels and output types. Ensure compatibility with the existing sensor wiring and voltage supply of the door operator. Confirm that the device meets the applicable safety standards required for the specific installation environment.
Safety Relays Selection Notes
Select this model based on the need for dual-channel safety evaluation to meet higher safety integrity levels. Consider the input requirements of the connected sensors and the output capacity needed for the door operator. Evaluate the physical mounting space and terminal block accessibility for installation constraints.
Safety Relays Part Context
This component belongs to the Mayser SG series of safety controllers, which are widely used in the automation of industrial doors. The SG-EFS series specifically focuses on edge protection and light curtain monitoring, providing a robust solution for preventing accidents during door operation in commercial and industrial settings.
Safety Relays Replacement Considerations
Public confirmed substitute part numbers: SG-EFS 104/2ZK/109L2X24V.