1090085

1090085

$1,484.20
  • Description:OLM100-1005 EXCHANGE 1045
  • Series:*
  • Mfr:SICK, Inc.
  • Package:Box

SKU:cef18418fb6c Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:OLM100-1005 EXCHANGE 1045
  • Series:*
  • Mfr:SICK, Inc.
  • Package:Box

Download product information

1090085

Overview

The SICK part number 1090085 corresponds to the TIM310-1030000, a LiDAR sensor utilizing the HDDM measurement principle. It operates with an infrared light source at 850 nm and is classified as Laser Class 1 under IEC60825-1:2014 and EN60825-1:2014 standards. The device features a horizontal aperture angle of 270 degrees and a scanning frequency of 15 Hz. Angular resolution is specified at 1 degree. The working range extends from 0.05 m to 4 m, while the scanning range at 10% remission is 2 m.

Feature Summary

  • Provides 270-degree horizontal scanning coverage for comprehensive area monitoring.
  • Ensures operator safety through Laser Class 1 classification compliant with international standards.
  • Delivers high angular resolution for precise object detection within the operational range.

Applications

  • Indoor automated guided vehicle (AGV) navigation and obstacle avoidance.
  • Safety monitoring in industrial automation environments.
  • Perimeter protection for machinery and robotic cells.

Procurement Notes

Verify that the ordering code matches 1090085 to ensure receipt of the TIM310-1030000 variant. Confirm compatibility with existing system interfaces and mounting requirements. Check for any specific regional certification requirements regarding Laser Class 1 compliance before deployment. Ensure environmental conditions remain within the specified operating temperature limits.

Selection Notes

Select this model when a wide 270-degree field of view is required for indoor applications. It is suitable for scenarios demanding Laser Class 1 safety without additional protective housing. Consider the 4-meter working range and 15 Hz scanning speed for dynamic environment monitoring. Verify that the 1-degree angular resolution meets the precision needs of the specific application.

Part Context

This component belongs to the TIM series of LiDAR sensors manufactured by SICK. The TIM series is designed for safety and non-safety applications in industrial settings. Part number 1090085 specifically identifies the TIM310-1030000 configuration, which is optimized for indoor use with a defined scanning range and laser safety class.

Replacement Considerations

Publicly confirmed substitute part numbers are not available in the provided documentation. Consult SICK technical support for cross-referencing compatible models if replacement is necessary.

FAQ

What is the laser safety class of the TIM310-1030000?

It is classified as Laser Class 1 according to IEC60825-1:2014 and EN60825-1:2014.

What is the maximum scanning range at 10% remission?

The scanning range at 10% remission is 2 meters.

10900851090085
$1,484.20
Buy Now