1182F30 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Hammond Manufacturing. Its product description is PWR XFMR TOROIDAL 225VA CHAS MT. Review the specifications below when checking this part for your BOM.
Power Transformers specifications for 1182F30
- Description:PWR XFMR TOROIDAL 225VA CHAS MT
- Series:1182
- Mfr:Hammond Manufacturing
- Package:Box
- Type:Toroidal
- Voltage - Primary:117V, 234V
- Voltage - Secondary (Full Load):Parallel 30V, Series 60V
- Current - Output (Max):Parallel 7.5A, Series 3.75A
- Primary Winding(s):Dual
- Secondary Winding(s):Dual
- Center Tap:No
- Power - Max:225VA
- Mounting Type:Chassis Mount
- Termination Style:Wire Leads
- Size / Dimension:114.30mm Dia
- Height - Seated (Max):47.75mm
- Voltage - Isolation:4000Vrms
- Weight:4.7 lbs (2.1 kg)
Power Transformers datasheet and documents for 1182F30
Power Transformers Overview
The Hammond Manufacturing 1182F30 is a toroidal power transformer rated at 225 VA. It features dual primary windings supporting 115 VAC and 230 VAC input configurations. The secondary output provides a center-tapped 60 VAC configuration at 3.75 A, alongside a separate 30 VAC winding rated at 7.5 A. Designed for chassis mounting with wire lead terminations, this unit operates at 50 Hz or 60 Hz frequencies. The assembly utilizes a low-profile core shape to minimize stray magnetic flux leakage.
Power Transformers Feature Summary
- Toroidal core construction reduces stray magnetic flux leakage and electromagnetic interference
- Dual primary winding capability allows flexible connection to 115 VAC or 230 VAC supply lines
- Chassis mount design facilitates secure integration into industrial control enclosures
Power Transformers Applications
- Industrial control panel power supplies
- General purpose equipment requiring isolated AC power
- Audio amplifier power stages
- Test and measurement instrument internal power systems
Power Transformers Procurement Notes
Verify the specific secondary voltage configuration required for your application before ordering. Confirm that the chassis mounting dimensions and wire lead lengths meet your enclosure constraints. Ensure the input voltage matches the primary winding setup. Check regulatory compliance documentation for your target market requirements. Contact the manufacturer for detailed dimensional drawings if space is limited.
Power Transformers Selection Notes
Select this model when a 225 VA capacity is needed with dual secondary outputs of 60 VAC CT and 30 VAC. Consider the physical height and weight constraints of the installation site. Evaluate the need for low EMI characteristics provided by the toroidal design. Compare against other series models if different voltage ratios or power ratings are required.
Power Transformers Part Context
This component belongs to the Hammond 1182 series of toroidal transformers. The series offers various power ratings from 80 VA to 1500 VA. These units are characterized by high efficiency and compact profiles. The 1182F30 specifically addresses applications needing multiple secondary voltages from a single core.
Power Transformers Replacement Considerations
No direct substitute part numbers are publicly confirmed in the provided documentation. Verify compatibility with existing wiring and mounting hardware if considering alternative manufacturers.
Explore related parts through Transformers, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier