1182K30 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Hammond Manufacturing. Its product description is PWR XFMR TOROIDAL 80VA CHAS MT. Review the specifications below when checking this part for your BOM.
Power Transformers specifications for 1182K30
- Description:PWR XFMR TOROIDAL 80VA CHAS MT
- Series:1182
- Mfr:Hammond Manufacturing
- Package:Box
- Type:Toroidal
- Voltage - Primary:117V, 234V
- Voltage - Secondary (Full Load):Parallel 30V, Series 60V
- Current - Output (Max):Parallel 2.66A, Series 1.33A
- Primary Winding(s):Dual
- Secondary Winding(s):Dual
- Center Tap:No
- Power - Max:80VA
- Mounting Type:Chassis Mount
- Termination Style:Wire Leads
- Size / Dimension:88.90mm Dia
- Height - Seated (Max):38.10mm
- Voltage - Isolation:4000Vrms
- Weight:2.1 lbs (952.5 g)
Power Transformers datasheet and documents for 1182K30
Power Transformers Overview
The Hammond Manufacturing 1182K30 is a toroidal power transformer designed for industrial control applications. It features a dual primary winding configuration supporting 115 VAC and 230 VAC input voltages, with a rated power capacity of 80 VA. The unit operates at standard frequencies of 50 Hz and 60 Hz. Electrical output specifications include a center-tapped secondary providing 60VCT at 1.33A and an additional 30V tap at 2.66A. The component utilizes wire leads for termination and is intended for chassis mounting. Physical dimensions are not explicitly defined in the provided source data.
Power Transformers Feature Summary
- Toroidal core construction for efficient magnetic coupling
- Dual primary windings for flexible voltage compatibility
- Multiple secondary voltage taps for varied load requirements
Power Transformers Applications
- Industrial automation systems
- Embedded electronics power supplies
- Control panel power distribution
Power Transformers Procurement Notes
Verify the specific secondary configuration against project requirements, as the model supports both 60VCT and 30V outputs. Confirm that the 80 VA rating meets the total load demand including surge currents. Ensure the chassis mounting style aligns with the enclosure design. Check RoHS compliance status through official manufacturer documentation before finalizing procurement.
Power Transformers Selection Notes
Select this model when a compact toroidal transformer is required for 80 VA applications. The dual primary winding allows operation in regions with either 115 VAC or 230 VAC mains. The multiple secondary options provide flexibility for circuits needing different voltage levels from a single unit. Verify that the wire lead termination method is suitable for the target assembly process.
Power Transformers Part Context
This component belongs to the Hammond 1182 series of industrial control transformers. The series offers various power ratings and secondary configurations tailored for general-purpose industrial use. The 1182K30 specifically addresses needs for moderate power levels with versatile output options. It is categorized under toroidal transformers within the broader power transformer product line.
Power Transformers Replacement Considerations
No direct substitute part numbers are confirmed in the public documentation. Evaluate other models within the 1182 series based on matching VA ratings and secondary voltage configurations. Ensure any alternative maintains the same physical mounting constraints and electrical specifications.
Explore related parts through Transformers, all product categories, ChipApex homepage.