160D40 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Hammond Manufacturing. Its product description is PWR XFMR LAMINATED 1VA TH. Review the specifications below when checking this part for your BOM.
Power Transformers specifications for 160D40
- Description:PWR XFMR LAMINATED 1VA TH
- Series:160
- Mfr:Hammond Manufacturing
- Package:Bulk
- Type:Laminated Core
- Voltage - Primary:115V, 230V
- Voltage - Secondary (Full Load):Parallel 20V, Series 40V
- Current - Output (Max):Parallel 40mA, Series 20mA
- Primary Winding(s):Dual
- Secondary Winding(s):Single, Multiple Taps
- Center Tap:No
- Power - Max:1VA
- Mounting Type:Through Hole
- Termination Style:PC Pin
- Size / Dimension:25.40mm L x 35.05mm W
- Height - Seated (Max):21.08mm
- Voltage - Isolation:2000Vrms
- Weight:0.13 lb (58.97 g)
Power Transformers datasheet and documents for 160D40
Power Transformers Overview
The Hammond Manufacturing 160D40 is a low voltage power transformer designed for printed circuit board (PCB) mounting. It features dual primary windings rated for 115 VAC and 230 VAC operation at 50 Hz or 60 Hz frequencies. The secondary output provides 40 VAC center-tapped configuration with a current rating of 20 mA, delivering a total power capacity of 1 VA. The unit utilizes solder pin termination for secure electrical connections and operates within a temperature range of 0°C to +130°C.
Power Transformers Feature Summary
- Dual primary winding design supports versatile input voltage requirements
- Center-tapped secondary output enables specific rectification configurations
- Solder pin termination ensures stable PCB integration
Power Transformers Applications
- Low voltage electronic circuit power supplies
- Industrial control panel instrumentation
- Consumer electronics internal power regulation
Power Transformers Procurement Notes
Verify the exact secondary specifications against official datasheets prior to procurement. Confirm that the 40VCT @ 20mA rating aligns with your circuit design requirements. Ensure compatibility with standard through-hole assembly processes. Check for RoHS compliance status if required by your manufacturing standards. Validate physical dimensions against your PCB layout constraints.
Power Transformers Selection Notes
Select this component when a compact, low-power transformer is needed for direct PCB integration. The dual primary winding allows flexibility for different regional input voltages without changing hardware. Consider the thermal limits and ensure adequate ventilation for operation near the maximum temperature rating. Verify that the 1 VA power budget meets the load requirements of the downstream circuitry.
Power Transformers Part Context
This part belongs to the Hammond 160 series of low voltage power transformers. These components are engineered for general-purpose applications requiring isolated AC-to-AC conversion. The series offers various voltage and current combinations to suit diverse electronic design needs while maintaining a standardized footprint for easy substitution within compatible designs.
Power Transformers Replacement Considerations
Consult official Hammond Manufacturing documentation for verified substitute part numbers. Cross-reference secondary voltage and current ratings carefully to ensure functional equivalence. Verify that alternative components match the physical mounting style and terminal type.
Explore related parts through Transformers, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier