2420920000 is listed in the Current Sense Transformers range at ChipApex. The manufacturer field lists Weidmüller. Its product description is CMA-31-400-5A-5VA-1. Review the specifications below when checking this part for your BOM.
Current Sense Transformers specifications for 2420920000
- Description:CMA-31-400-5A-5VA-1
- Series:-
- Mfr:Weidmüller
- Package:Box
- Frequency Range:50Hz
- Type:Non-Invasive (Solid Core)
- Inductance:-
- ET (Volt-Time):-
- Current Ratio:-
- DC Resistance (DCR):-
- Ratings:-
- Mounting Type:DIN Rail
- Size / Dimension:2.362" L x 2.047" W (60.00mm x 52.00mm)
- Height - Seated (Max):3.185" (80.90mm)
- Termination Style:Terminal Block
- Turns Ratio - Primary:Secondary:-
- Current Rating (Amps):400 A
Current Sense Transformers datasheet and documents for 2420920000
Current Sense Transformers Overview
The Weidmüller 2420920000 is a CMA-31-400-5A-5VA-1 current transformer designed for precise measurement of load current consumption using RMS value methods. It features a rated primary current of 400 A and a secondary output of 5 A, with a maximum operating voltage of 400 VDC. The device supports a rated residual current of 400 mA and operates within a temperature range of -25°C to +70°C. Measuring 52 mm in length, it utilizes a terminal block termination style and is intended for DIN rail mounting in industrial monitoring applications.
Current Sense Transformers Feature Summary
- Enables precise current consumption measurement via RMS value calculation
- Supports high-current sensing up to 400 A primary rating
- Designed for integration into industrial monitoring systems
Current Sense Transformers Applications
- Industrial monitoring systems requiring accurate current data
- Load current consumption measurement in automation setups
- DIN rail mounted electrical distribution panels
Current Sense Transformers Procurement Notes
Verify the specific datasheet version (CMA-31 series) to confirm terminal block compatibility and insulation ratings. Ensure the application environment stays within the specified -25°C to +70°C operational range. Confirm that the 400 VDC maximum operating voltage aligns with the system's electrical design requirements before procurement.
Current Sense Transformers Selection Notes
Select this component when a 400 A primary current rating and 5 A secondary output are required for RMS-based monitoring. Consider the 52 mm form factor for DIN rail space constraints. Validate that the terminal block termination style matches existing wiring infrastructure and that the 400 mA residual current capability meets safety standards.
Current Sense Transformers Part Context
This part belongs to the CMA-31 series of current transformers from Weidmüller, engineered for industrial-grade performance. It complements other models like 2420980000 by offering a standardized 5 A output for consistent interfacing with downstream measurement devices and control systems in heavy-duty environments.
Current Sense Transformers Replacement Considerations
No public confirmed substitute part numbers are available in the provided documentation.
Explore related parts through Transformers, all product categories, ChipApex homepage.