2511690000 is listed in the Current Sense Transformers range at ChipApex. The manufacturer field lists Weidmüller. Its product description is KCMA-18-50-1A-1VA-3 HUT. Review the specifications below when checking this part for your BOM.
Current Sense Transformers specifications for 2511690000
- Description:KCMA-18-50-1A-1VA-3 HUT
- Series:-
- Mfr:Weidmüller
- Package:Box
- Frequency Range:50Hz
- Type:Non-Invasive (Split Core)
- Inductance:-
- ET (Volt-Time):-
- Current Ratio:-
- DC Resistance (DCR):-
- Ratings:-
- Mounting Type:Free Hanging (In-Line)
- Size / Dimension:2.650" L x 1.638" W (67.30mm x 41.60mm)
- Height - Seated (Max):2.539" (64.50mm)
- Termination Style:Wire Leads
- Turns Ratio - Primary:Secondary:-
- Current Rating (Amps):50 A
Current Sense Transformers datasheet and documents for 2511690000
Current Sense Transformers Overview
The Weidmüller 2511690000 is a split-core current transformer designed for non-invasive measurement of alternating current. It features a primary rated current of 50 A and a secondary nominal output of 1 A. The device supports a maximum burden load of 1 VA and adheres to accuracy class 3 standards. With dimensions of 67.30 mm in length and 1.638 inches in width, it utilizes a free-hanging in-line mounting configuration. The unit operates within a temperature range of -25°C to 70°C and is suitable for 50 Hz frequency applications.
Current Sense Transformers Feature Summary
- Split-core design enables installation without disconnecting the primary conductor
- Utilizes rms value methods for precise current consumption measurement
- Asymmetrical cable feed-through facilitates straightforward integration
Current Sense Transformers Applications
- Measurement of current consumption in electrical loads
- Integration into monitoring systems requiring non-invasive sensing
- Industrial equipment current tracking
Current Sense Transformers Procurement Notes
Verify that the required secondary current matches the 1 A specification and confirm the burden load does not exceed 1 VA. Ensure the primary circuit current remains within the 50 A rating. Check that the operating environment stays within the -25°C to 70°C range. Confirm compatibility with 50 Hz systems. Validate physical space constraints against the specified dimensions before ordering.
Current Sense Transformers Selection Notes
Select this component when non-invasive current measurement is required for circuits up to 50 A. It is appropriate for applications where breaking the primary conductor is impractical. Consider the 1 A secondary output and 1 VA burden limit when designing the connected measurement circuitry. Ensure the accuracy class 3 meets the system requirements. Verify that the free-hanging mounting style fits the installation environment.
Current Sense Transformers Part Context
This part belongs to the Weidmüller current transformer series, specifically engineered for commercialized industrial applications. The model KCMA-18-50-1A-1VA-3 HUT represents a standardized solution for current sensing. It is distinct from invasive ring-type transformers due to its split-core architecture. The product status is confirmed as commercialized, indicating availability for standard procurement channels.
Current Sense Transformers Replacement Considerations
Publicly confirmed substitute part numbers are not available in the provided documentation. Cross-referencing requires matching primary current ratings, secondary output specifications, and physical dimensions. Verify that any alternative component maintains the same accuracy class and burden capacity.
Explore related parts through Transformers, all product categories, ChipApex homepage.