Power Transformers 6054R-034 product image

6054R-034

  • Description:PWR XFMR LAMINATED 24VA TH
  • Series:6054R
  • Mfr:Delevan
  • Package:Bulk

SKU:6054R-034 Category: Brand:

ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

6054R-034 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Delevan. Its product description is PWR XFMR LAMINATED 24VA TH. Review the specifications below when checking this part for your BOM.

Power Transformers specifications for 6054R-034

  • Description:PWR XFMR LAMINATED 24VA TH
  • Series:6054R
  • Mfr:Delevan
  • Package:Bulk
  • Type:Laminated Core
  • Voltage - Primary:115V, 230V
  • Voltage - Secondary (Full Load):Parallel 17V, Series 34V
  • Current - Output (Max):Parallel 1.4A, Series 700mA
  • Primary Winding(s):Dual
  • Secondary Winding(s):Dual
  • Center Tap:No
  • Power - Max:24VA
  • Mounting Type:Through Hole
  • Termination Style:PC Pin
  • Size / Dimension:41.28mm L x 33.32mm W
  • Height - Seated (Max):33.32mm
  • Voltage - Isolation:1500Vrms
  • Weight:0.938 lb (425.47 g)

Power Transformers datasheet and documents for 6054R-034

6054R-034

Power Transformers Overview

The Delevan 6054R-034 is a laminated core power transformer designed for through-hole PCB mounting. It features dual primary windings rated for 115V and 230V input, providing versatile AC line compatibility. The unit includes dual secondary windings configured to deliver 48V at 500mA in parallel operation or 96V at 250mA in series configuration. With a maximum power rating of 24VA, this component offers high isolation voltage and robust construction suitable for demanding industrial applications.

Power Transformers Feature Summary

  • Dual primary winding design supports both 115V and 230V AC input configurations
  • Dual secondary windings allow flexible output selection between parallel and series modes
  • Laminated core construction ensures stable performance under varying load conditions
  • High isolation voltage capability provides enhanced safety for sensitive circuitry

Power Transformers Applications

  • Industrial control systems requiring isolated DC power supplies
  • Medical equipment needing certified electrical isolation
  • Test and measurement instruments with variable input requirements
  • Communication hardware utilizing standard AC mains voltages

Power Transformers Procurement Notes

Verify the specific datasheet version before procurement, as API Delevan product specifications may undergo revisions. Confirm that the required isolation voltage and thermal characteristics align with your system's safety standards. Ensure the physical dimensions match your PCB layout constraints. Check for any recent discontinuance notices or lifecycle changes from the manufacturer. Validate compliance with relevant regional regulatory requirements prior to finalizing orders.

Power Transformers Selection Notes

Select this model when dual input voltage flexibility is required without separate transformers. Consider the physical size and weight limitations of your enclosure. Evaluate the thermal dissipation requirements based on the 24VA power rating. Ensure the through-hole mounting style fits your assembly process. Compare the isolation voltage against your application's safety clearance needs. Verify that the secondary current ratings meet the peak load demands of your circuit.

Power Transformers Part Context

This component belongs to the 6054R series of power transformers manufactured by API Delevan. The series utilizes laminated core technology for reliable power conversion. Similar models in the family offer different voltage ratios and power ratings while maintaining consistent mounting styles. The 6054R-034 specifically addresses applications needing dual secondary outputs from a single compact unit.

Power Transformers Replacement Considerations

Public confirmed substitute part numbers are not available in the provided documentation. Consult the manufacturer directly for cross-reference information. Verify that any alternative component matches the electrical parameters and physical footprint. Ensure replacement parts maintain equivalent isolation and safety certifications.

6054R-0346054R-034

Click on the inquiry