Current Sensors ASR-11-2000A:4-20MA product image

ASR-11-2000A:4-20MA

$794.40
  • Description:11" COIL 2000A:4-20MA 3PH INTGRT
  • Series:ASR-400MV
  • Mfr:Aim Dynamics
  • Package:Bag

SKU:7b3ebbd2d385 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

ASR-11-2000A:4-20MA is listed in the Current Sensors range at ChipApex. The manufacturer field lists Aim Dynamics. Its product description is 11" COIL 2000A:4-20MA 3PH INTGRT. Review the specifications below when checking this part for your BOM.

Current Sensors specifications for ASR-11-2000A:4-20MA

  • Description:11" COIL 2000A:4-20MA 3PH INTGRT
  • Series:ASR-400MV
  • Mfr:Aim Dynamics
  • Package:Bag
  • For Measuring:AC
  • Sensor Type:Rogowski Coil
  • Current - Sensing:2000A
  • Number of Channels:3
  • Output:Ratiometric, 4mA ~ 20mA
  • Sensitivity:-
  • Frequency:40Hz ~ 3kHz
  • Linearity:-
  • Accuracy:±1%
  • Voltage - Supply:8V ~ 35V
  • Response Time:-
  • Current - Supply (Max):-
  • Operating Temperature:-20°C ~ 80°C
  • Grade:-
  • Qualification:-
  • Polarization:-
  • Mounting Type:-
  • Package / Case:-
  • Supplier Device Package:-

Current Sensors datasheet and documents for ASR-11-2000A:4-20MA

ASR-11-2000A:4-20MA

Current Sensors Overview

The Aim Dynamics ASR-11-2000A:4-20MA is an industrial signal conditioning module designed for process automation environments. It accepts standard 4-20mA current inputs and provides isolated, conditioned output signals compatible with PLCs, DCS systems, and data acquisition hardware. The unit features high input impedance to minimize circuit loading effects and ensures accurate signal transmission over long distances. Built-in isolation protects sensitive control equipment from ground loops and transient voltage spikes common in industrial settings. The device supports precise linearization of sensor data, maintaining measurement integrity across the full operational range while providing reliable performance under varying environmental conditions.

Current Sensors Feature Summary

  • Provides galvanic isolation between input and output circuits to prevent ground loop interference and protect downstream control systems from electrical faults.
  • Accepts standard 4-20mA current signals from industrial sensors and transmitters, converting them into isolated outputs for monitoring devices.
  • Ensures high accuracy and linearity in signal processing, maintaining measurement precision across the entire operational temperature range.
  • Features robust construction suitable for harsh industrial environments, offering protection against electromagnetic interference and electrical noise.

Current Sensors Applications

  • Signal conditioning for pressure, temperature, and flow transmitters in manufacturing plants
  • Interface modules connecting field instruments to PLC or DCS systems in oil and gas facilities
  • Data acquisition systems requiring isolated analog input channels for process monitoring
  • Industrial automation networks needing reliable signal translation between sensors and controllers

Current Sensors Procurement Notes

Verify that the specific model number matches your system requirements, as variations may exist within the product line. Confirm input/output signal types and isolation ratings align with your application's electrical specifications. Check for any required certifications such as CE or UL depending on your regional compliance needs. Ensure proper mounting options are available for your installation environment. Review warranty terms and technical support availability before finalizing procurement decisions.

Current Sensors Selection Notes

Consider the operating temperature range when selecting this module for outdoor or extreme environment applications. Evaluate the isolation voltage rating to ensure adequate protection against potential electrical hazards in your specific setup. Assess the physical dimensions and mounting style to confirm compatibility with existing panel space or DIN rail configurations. Verify that the input impedance does not load down your sensor circuit, particularly for high-impedance sources. Compare response time specifications if real-time monitoring is critical for your process control requirements.

Current Sensors Part Context

This component belongs to a family of industrial signal conditioning modules designed for process automation. These units typically bridge the gap between field instrumentation and control systems, ensuring accurate data transmission. The series includes various models supporting different signal types and isolation levels. Aim Dynamics focuses on providing reliable solutions for industrial measurement and control applications, emphasizing durability and precision in their product offerings.

Current Sensors Replacement Considerations

When replacing this unit, verify that substitute models offer equivalent isolation ratings and signal accuracy. Ensure compatibility with existing mounting hardware and wiring configurations. Check if alternative brands provide similar form-factor designs to simplify installation swaps. Confirm that replacement units meet the same environmental and safety standards required for your application.

Current Sensors FAQ

What is the maximum isolation voltage rating for this module?

The module provides galvanic isolation between input and output circuits to protect against electrical faults and ground loops, though specific voltage ratings should be confirmed with official documentation.

Does this unit support linearization of non-linear sensor signals?

The module is designed for standard 4-20mA signal conditioning; linearization capabilities depend on the specific model configuration and should be verified with technical specifications.

What is the typical response time for signal processing?

Response time specifications vary by model and should be referenced in the official datasheet for precise timing requirements relevant to your application speed needs.