Product Detailed Parameters
- Description:PWR XFMR LAMINATED 56VA CHAS MT
- Series:Two-4-One™
- Mfr:Signal Transformer
- Package:Box
- Type:Laminated Core
- Voltage - Primary:115V, 230V
- Voltage - Secondary (Full Load):10V
- Current - Output (Max):5A
- Primary Winding(s):Dual
- Secondary Winding(s):Single
- Center Tap:Yes
- Power - Max:56VA
- Mounting Type:Chassis Mount
- Termination Style:Solder, Quick Connect
- Size / Dimension:93.70mm L x 49.20mm W
- Height - Seated (Max):57.80mm
- Voltage - Isolation:2500Vrms
- Weight:1.7 lbs (771.1 g)
Download product information
Overview
The DP-241-7-10 is a single-phase industrial power transformer from the Bel Signal Transformer Two-for-One series. It features a laminated core with dual primary windings rated for 115 VAC and 230 VAC operation at 50 Hz or 60 Hz frequencies. The unit provides a secondary voltage of 10 VCT with a current rating of 5 A, delivering a total power capacity of 56 VA. Designed for chassis mounting, it utilizes quick connect and solder lug terminals for electrical interfacing. The component operates within a temperature range of -40°C to +105°C and offers 2500 Vrms dielectric strength.
Feature Summary
- Utilizes a split bobbin design to ensure superior isolation and low capacitive coupling between windings.
- Supports flexible input configuration through dual primary windings compatible with both 115 VAC and 230 VAC systems.
- Constructed with a laminated core architecture optimized for standard 50 Hz and 60 Hz industrial power frequencies.
Applications
- Industrial control panel power supply circuits
- Chassis-mounted equipment requiring isolated AC power conversion
- General purpose power distribution in electronic instrumentation
Procurement Notes
Verify that the specific terminal type matches the system requirements, as this model supports both quick connects and solder lugs. Confirm the primary voltage setting aligns with the available line voltage (115V or 230V) before installation. Ensure the chassis mounting holes correspond to the physical dimensions provided in the official datasheet. Check for RoHS compliance status if environmental regulations apply to the final assembly.
Selection Notes
Select this transformer when a 56 VA capacity is required for applications needing a 10 VCT output. The dual primary winding capability makes it suitable for global deployment across different mains voltage standards. Consider the chassis mount style and terminal options during mechanical integration planning. Verify thermal management requirements against the maximum operating temperature limit of +105°C.
Part Context
This component belongs to the DP-241 series of industrial power transformers manufactured by Bel Signal Transformer. The series is characterized by robust construction and high isolation capabilities using split bobbin technology. These units are designed for reliability in demanding industrial environments, offering standardized form factors for easy integration into existing control systems and power infrastructure.
Replacement Considerations
Consult official cross-reference lists for direct equivalents. Ensure any substitute maintains the 56 VA rating, 10 VCT secondary output, and dual primary compatibility. Verify mechanical footprint and terminal types match the original design constraints.
FAQ
What is the dielectric strength of the DP-241-7-10?
The transformer provides a dielectric strength of 2500 Vrms between windings.
How does the split bobbin design benefit this transformer?
The split bobbin construction provides superior isolation and minimizes capacitive coupling between the primary and secondary windings.