Power Transformers F-94X product image

F-94X

$11.38
  • Description:PWR XFMR LAMINATED VARIES CHAS
  • Series:Universal
  • Mfr:Triad Magnetics
  • Package:Box

SKU:F-94X Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

F-94X is listed in the Power Transformers range at ChipApex. The manufacturer field lists Triad Magnetics. Its product description is PWR XFMR LAMINATED VARIES CHAS. Review the specifications below when checking this part for your BOM.

Power Transformers specifications for F-94X

  • Description:PWR XFMR LAMINATED VARIES CHAS
  • Series:Universal
  • Mfr:Triad Magnetics
  • Package:Box
  • Type:Laminated Core
  • Voltage - Primary:115V
  • Voltage - Secondary (Full Load):40V, 20V, 10V
  • Current - Output (Max):35mA
  • Primary Winding(s):Single, Multiple Taps
  • Secondary Winding(s):Single
  • Center Tap:Yes
  • Power - Max:Varies
  • Mounting Type:Chassis Mount
  • Termination Style:Wire Leads
  • Size / Dimension:60.33mm L x 34.93mm W
  • Height - Seated (Max):34.93mm
  • Voltage - Isolation:1500Vrms
  • Weight:0.5 lb (226.8 g)

Power Transformers datasheet and documents for F-94X

F-94X

Power Transformers Overview

The Triad Magnetics F-94X is an industrial power transformer designed for chassis mounting with wire leads. It features a single primary winding rated for 115VAC input and a center-tapped secondary winding providing 7.0V to 40.0VCT at a current rating of 0.035A. The unit has a power rating of approximately 1.4VA. It utilizes a laminated core construction typical of the F series, ensuring reliable performance in control applications requiring low-current step-down or isolation from standard line voltage.

Power Transformers Feature Summary

  • Chassis mount design with integrated wire leads for direct circuit connection
  • Single primary winding configuration compatible with 115VAC supply lines
  • Center-tapped secondary output enabling flexible voltage selection between 7.0V and 40.0VCT
  • Laminated core construction optimized for industrial control environments

Power Transformers Applications

  • Low-power industrial control circuits requiring isolated power sources
  • Electronic equipment needing stepped-down AC voltage for rectification
  • Signal processing stages utilizing center-tapped transformer configurations
  • Custom instrumentation power supplies operating within low current limits

Power Transformers Procurement Notes

Verify that the application current does not exceed the 0.035A rating to prevent thermal overload. Confirm the 115VAC primary requirement matches the local supply infrastructure. Ensure chassis mounting provisions accommodate the physical dimensions and lead lengths specified in the official datasheet. Check for specific regulatory compliance markings required by the end-use market.

Power Transformers Selection Notes

Select this component when a fixed 115VAC input and low-current center-tapped output are required. Consider the F-94X for designs prioritizing simple chassis integration over PCB footprint constraints. Evaluate if the 0.035A limit suffices for downstream load demands. Compare against other F-series models if higher power or different voltage ratios are necessary for the system architecture.

Power Transformers Part Context

The F-94X belongs to Triad Magnetics' F series of industrial power transformers. This series is characterized by robust laminated cores and versatile mounting options suitable for panel or chassis installation. These transformers are engineered for durability in demanding industrial settings, offering standardized form factors that simplify mechanical design and integration into larger electrical assemblies.

Power Transformers FAQ

What is the secondary voltage configuration?

The secondary winding is center-tapped (CT), providing a variable range from 7.0V to 40.0VCT.

Is the primary winding dual-coil?

No, the F-94X features a single primary winding rated for 115VAC operation.

F-94XF-94X
$11.38