JC10F-010A-V is listed in the Current Sensors range at ChipApex. The manufacturer field lists J&D Manufacturing. Its product description is 10MM CURRENT TRANS 10A:5VDC. Review the specifications below when checking this part for your BOM.
The JC10F-010A-V is a split-core current transducer manufactured by J&D Manufacturing, designed for the electronic measurement of AC waveform currents. It features galvanic isolation between the primary power circuit and secondary output. The device has a sensing capacity of 10 Amperes with a ratiometric voltage output ranging from 0V to 5Vdc. Key performance specifications include an accuracy of ±2%, linearity of ±2%, and a response time of 300ms. It operates within a temperature range of -20°C to 50°C and supports frequencies of 50Hz to 60Hz.
Verify that the required sensing current matches the specific model suffix (e.g., 010A for 10 Amps) as the series offers multiple input ratings. Confirm that the application frequency aligns with the 50Hz to 60Hz specification. Ensure the mounting environment falls within the stated operating temperature range of -20°C to 50°C. Check that the load impedance is compatible with the 0-5Vdc output requirements of the receiving instrumentation.
Select this component when a non-invasive current measurement solution is required for AC circuits up to 10 Amperes. The split-core architecture is ideal for retrofitting existing installations where conductor removal is not feasible. Choose this model if the system requires a simple ratiometric voltage output rather than a current loop. Consider the ±2% accuracy rating against the precision needs of the specific energy monitoring application.
This part belongs to the JC10F-XXX-V series of split-core current transducers from J&D Manufacturing. The series is characterized by its V-series output configuration and modular design for various current ranges. These transducers are positioned as components for energy management hardware, providing a standardized interface for measuring AC loads in modern electrical infrastructure.
Publicly confirmed substitute part numbers are not available in the provided documentation. When evaluating alternatives, ensure the replacement maintains the same 10A sensing range, 0-5Vdc ratiometric output, and split-core mechanical form factor. Verify compatibility with the target electronic submeter's input specifications.
Explore related parts through Sensors, Transducers, all product categories, ChipApex homepage.