Power Transformers K13E2H75S product image

K13E2H75S

$4,298.67
  • Description:PWR XFMR LAMINATED 75000VA CHAS
  • Series:E2
  • Mfr:SolaHD
  • Package:Bulk

SKU:K13E2H75S Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

K13E2H75S is listed in the Power Transformers range at ChipApex. The manufacturer field lists SolaHD. Its product description is PWR XFMR LAMINATED 75000VA CHAS. Review the specifications below when checking this part for your BOM.

Power Transformers specifications for K13E2H75S

  • Description:PWR XFMR LAMINATED 75000VA CHAS
  • Series:E2
  • Mfr:SolaHD
  • Package:Bulk
  • Type:Laminated Core
  • Voltage - Primary:480V
  • Voltage - Secondary (Full Load):-
  • Current - Output (Max):208A
  • Primary Winding(s):Dual, Multiple Taps
  • Secondary Winding(s):Single, Multiple Taps
  • Center Tap:Yes
  • Power - Max:75000VA
  • Mounting Type:Chassis Mount
  • Termination Style:Solder, Quick Connect
  • Size / Dimension:-
  • Height - Seated (Max):-
  • Voltage - Isolation:-
  • Weight:-

Power Transformers datasheet and documents for K13E2H75S

K13E2H75S

Power Transformers Overview

The SolaHD K13E2H75S is a three-phase power transformer with a 75 kVA rating and K-13 certification. It features a 480V primary voltage and provides dual secondary outputs of 208Y/120V. The unit utilizes a ventilated construction design suitable for industrial environments. Electrical specifications include a maximum output current of 196A at full load. The transformer employs wire lead terminations for connection and is designed for base mounting installation. Physical dimensions are approximately 483mm in length, 584mm in width, and 711mm in height.

Power Transformers Feature Summary

  • K-13 rated construction designed to withstand harmonic currents from non-linear loads
  • Ventilated design ensures thermal management without enclosed housing restrictions
  • Triple primary winding configuration allows for flexible input voltage compatibility
  • Dual secondary windings provide simultaneous 208Y and 120V output capabilities

Power Transformers Applications

  • Power distribution systems serving computer networks and data processing equipment
  • Industrial facilities utilizing variable frequency drives (VFDs) and rectifier loads
  • Commercial buildings with significant lighting ballast or electronic power supply loads
  • Manufacturing plants requiring isolation from harmonic distortion generated by machinery

Power Transformers Procurement Notes

Verify the specific K-factor rating requirement against the load profile to ensure the K-13 designation meets the harmonic mitigation needs of the application. Confirm that the physical footprint and base mounting provisions align with the available installation space. Ensure the primary voltage matches the source supply exactly. Check termination style requirements to confirm wire lead compatibility with existing busbar or cable connections. Validate that the ventilation clearance requirements are met in the installation environment to maintain thermal performance.

Power Transformers Selection Notes

Select this model when the electrical load generates significant triplen harmonics that require a K-13 tolerance level. Choose based on the need for a single unit to provide both 208V and 120V services from a 480V source. Consider the ventilated construction if the installation area allows for adequate airflow around the core and coils. Evaluate the base mounting option if floor or structural steel mounting is preferred over wall or rack installation. Compare the physical dimensions against the site constraints to ensure fitment.

Power Transformers Part Context

This component belongs to the SolaHD K-Factor series of transformers, which are engineered specifically for applications involving non-linear loads. The series includes various ratings and K-factor certifications to address different levels of harmonic distortion. The K13E2H75S represents a mid-range capacity unit within this family, balancing power delivery with harmonic resilience. It is part of a broader line of industrial power solutions designed to protect sensitive equipment from power quality issues common in modern electrical systems.

Power Transformers Replacement Considerations

Direct replacements must match the 75 kVA rating, 480V primary, and 208Y/120V secondary voltages. Verify that any substitute also carries a K-13 rating to maintain harmonic protection standards. Ensure the replacement supports the same triple primary winding configuration for voltage flexibility. Check that the physical mounting type and terminal style are compatible with existing infrastructure. Consult manufacturer cross-reference lists for verified equivalent part numbers.