LP-20-2400 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Signal Transformer. Its product description is PWR XFMR SEMI-TORO 48VA TH. Review the specifications below when checking this part for your BOM.
Power Transformers specifications for LP-20-2400
- Description:PWR XFMR SEMI-TORO 48VA TH
- Series:LP
- Mfr:Signal Transformer
- Package:Bulk
- Type:Semi-Toroidal
- Voltage - Primary:115V, 230V
- Voltage - Secondary (Full Load):Parallel 10V, Series 20V
- Current - Output (Max):Parallel 4.8A, Series 2.4A
- Primary Winding(s):Dual
- Secondary Winding(s):Dual
- Center Tap:No
- Power - Max:48VA
- Mounting Type:Through Hole
- Termination Style:PC Pin
- Size / Dimension:79.20mm L x 63.50mm W
- Height - Seated (Max):34.90mm
- Voltage - Isolation:1500Vrms
- Weight:1.4 lbs (635 g)
Power Transformers datasheet and documents for LP-20-2400
Power Transformers Overview
The LP-20-2400 is a low-profile laminated power transformer from the LP series by Signal Transformer. It features dual primary windings rated for 115 VAC and 230 VAC inputs, supporting 50 Hz and 60 Hz operation. The unit provides dual secondary outputs: 20 VCT at 2.40 A or 10 V at 4.80 A, delivering a total power rating of 48 VA. Designed for through-hole mounting, it measures 79.2 mm in length with a compact height range typical of the series.
Power Transformers Feature Summary
- Utilizes hum-bucking semi-toroidal construction to minimize electromagnetic interference
- Offers flexible input voltage compatibility via dual primary windings
- Provides versatile secondary output configurations for rectifier applications
Power Transformers Applications
- Industrial control systems requiring low-profile power solutions
- Rectifier circuits needing specific current and voltage ratios
- Equipment constrained by vertical space limitations
Power Transformers Procurement Notes
Verify the exact secondary current ratings against the official datasheet, as configurations may vary within the LP series. Confirm that the through-hole mounting style aligns with your PCB design requirements. Ensure the operating frequency matches your system's supply standards. Cross-reference the physical dimensions to guarantee fitment within the intended enclosure space before finalizing procurement.
Power Transformers Selection Notes
Select this component when a 48 VA capacity is required in a low-profile form factor. The dual primary winding allows direct connection to either 115 VAC or 230 VAC mains without rewiring. Consider the semi-toroidal construction if noise reduction is critical. Ensure the through-hole package is compatible with your assembly process and that the physical footprint fits the designated board area.
Power Transformers Part Context
This model belongs to the LP series of low-profile transformers manufactured by Signal Transformer. The series utilizes hum-bucking technology to enhance performance in sensitive environments. These units are designed for general-purpose power transformation in industrial and commercial applications where space efficiency and electrical isolation are prioritized.
Power Transformers Replacement Considerations
Consult official substitution guides for equivalent models within the LP series or alternative manufacturers offering similar 48 VA through-hole transformers. Verify that any replacement maintains the same pinout, voltage ratings, and physical envelope dimensions to ensure seamless integration into existing designs.
Explore related parts through Transformers, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier