The LT6660KCDC-5#TRMPBF is a micropower series voltage reference from Analog Devices, housed in a 3-lead 2mm × 2mm × 0.75mm DFN package. It provides a fixed 5V output with an initial accuracy of ±0.5% and a maximum temperature coefficient of 50ppm/°C. The device guarantees a 20mA output current and operates within an input voltage range of VOUT + 0.9V to 20V. Supply current is typically 200µA at 25°C. It features reverse-battery protection and requires no output compensation capacitor.
Verify the specific suffix #TRMPBF indicates tape and reel packaging with lead-free compliance. Confirm the KCDC designation corresponds to the 0.5% accuracy grade and 50ppm/°C temperature coefficient. Ensure the operating environment stays within the specified 0°C to 70°C range for guaranteed electrical characteristics. Check for any regional distribution restrictions or limited availability status before finalizing procurement plans.
Select this component when a small footprint is critical but higher accuracy than shunt references is required. The KCDC variant offers a balance of cost and performance with 0.5% accuracy. Consider the 50ppm/°C drift if operating across wide temperature ranges. Compare against the LT1460 for applications requiring larger packages or tighter tolerances. Ensure input voltage remains above VOUT + 0.9V for proper regulation.
This part belongs to the LT6660 family of tiny micropower precision series references. The family includes options for 2.5V, 3V, 3.3V, 5V, and 10V outputs. Variants are available in HC (0.2%), JC (0.4%), and KC (0.5%) accuracy grades. All share the same 3-lead DFN package and core architecture designed for low power dissipation and high stability in space-constrained designs.
LT6660KCDC-5#TRPBF: Identical electrical specifications and accuracy grade; differs only in tape and reel packaging quantity or handling format.
No, the LT6660 family is designed to be stable without an output compensation capacitor, which helps minimize PCB space and settling time.
The device requires a minimum dropout voltage of 0.9V to maintain regulation under no-load conditions.
The KCDC variant has a maximum initial accuracy of ±0.5% and a maximum temperature coefficient of 50ppm/°C, which is less precise than the HC (0.2%, 20ppm/°C) and JC (0.4%, 20ppm/°C) grades.