SEARCH
— IC芯片 | 连接器 | 传感器 | 被动器件 —
M4L-3-6-48 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Signal Transformer. Its product description is M4L 600VA WITH INPUT 100/115/200. Review the specifications below when checking this part for your BOM.
The Signal Transformer M4L-3-6-48 is a 600VA single-phase power transformer designed for chassis mounting. It features dual primary windings supporting 100V, 115V, 200V, and 230VAC inputs at 50/60Hz. The secondary configuration provides parallel 24V or series 48V outputs with corresponding current ratings of 25A (parallel) and 12.5A (series). Key electrical specifications include a dielectric strength of 4000 Vrms and RoHS compliance.
Verify that the specific application requires the 600VA rating and the exact secondary configuration (24V parallel or 48V series) before ordering. Confirm that the chassis mounting style aligns with the mechanical design of the target enclosure. Ensure the input voltage range matches the local power distribution network to avoid operational issues.
Select this model when a robust, general-purpose isolation transformer is needed for heavy loads up to 600VA. Consider the physical dimensions and weight constraints of the assembly, as chassis-mount transformers are typically heavier than PCB-mounted alternatives. Evaluate thermal management requirements based on the expected ambient temperature and load duty cycle.
This component belongs to the M4L series of power transformers from Signal Transformer, now part of Bel Fuse. The series is characterized by high reliability and standard chassis mounting formats suitable for OEM applications. The M4L-3-6-48 specifically addresses needs for medium-power isolation where dual primary flexibility is critical for global deployment.
Direct substitutes may include other 600VA chassis-mount transformers with identical pinouts and electrical ratings from manufacturers like Hammond or Triad. Verify that any replacement maintains the same dielectric strength and mounting hole pattern to ensure mechanical compatibility without redesigning the chassis.
No, the secondary windings are internally connected to provide either a parallel 24V output or a series 48V output. They cannot be utilized as two separate independent voltage sources simultaneously.
Specific maximum operating temperature limits are not provided in the available public documentation for this part number. Consult the manufacturer's datasheet for detailed thermal derating curves and class insulation ratings.
Explore related parts through Transformers, all product categories, ChipApex homepage.