Thermostats - Solid State MAX6505UTP030+T product image

MAX6505UTP030+T

  • Description:IC TEMP SWITCH DL TRIP SOT23-6
  • Series:-
  • Mfr:Analog Devices Inc./Maxim Integrated
  • Package:Tape & Reel (TR)

SKU:MAX6505UTP030+T Category: Brand:

ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

MAX6505UTP030+T is listed in the Thermostats - Solid State range at ChipApex. The manufacturer field lists Analog Devices Inc./Maxim Integrated. Its product description is IC TEMP SWITCH DL TRIP SOT23-6. Review the specifications below when checking this part for your BOM.

Thermostats - Solid State specifications for MAX6505UTP030+T

  • Description:IC TEMP SWITCH DL TRIP SOT23-6
  • Series:-
  • Mfr:Analog Devices Inc./Maxim Integrated
  • Package:Tape & Reel (TR)
  • Trip Temperature Threshold:Hot
  • Switching Temperature:30°C
  • Accuracy:±3.5°C
  • Current - Output (Max):20mA
  • Output Type:Open Drain
  • Output:Active Low
  • Output Function:/OverTemp, /Warn
  • Selectable Hysteresis:No
  • Features:Delta Select Inputs
  • Voltage - Supply:2.5 V ~ 5.5 V
  • Current - Supply:40µA
  • Operating Temperature:-40°C ~ 125°C
  • Mounting Type:Surface Mount
  • Package / Case:SOT-23-6
  • Supplier Device Package:SOT-6
  • Grade:-
  • Qualification:-

Thermostats - Solid State datasheet and documents for MAX6505UTP030+T

MAX6505UTP030+T

Thermostats - Solid State Overview

The MAX6505UTP030+T is a dual-trip temperature switch manufactured by Analog Devices Inc. (Maxim Integrated). It features an ALARM output that asserts when the die temperature exceeds a factory-programmed threshold of +30°C, and a WARN output that asserts at a lower temperature. The device utilizes a pin-selectable delta between thresholds (+5°C, +10°C, +20°C, or +30°C) and operates on a 2.5V to 5.5V supply with 40µA current consumption. It provides open-drain outputs in a SOT-23-6 package.

Thermostats - Solid State Feature Summary

  • Dual logic outputs for alarm and warning functions
  • Pin-selectable hysteresis between trip thresholds
  • Open-drain output configuration
  • Factory-programmed temperature accuracy

Thermostats - Solid State Applications

  • Thermal management systems
  • Overtemperature protection circuits
  • Consumer electronics thermal monitoring
  • Industrial equipment safety interlocks

Thermostats - Solid State Procurement Notes

Verify the specific suffix '030' confirms the +30°C trip threshold, as this varies across the MAX6505 family. Ensure the '+T' designation matches the required tape-and-reel packaging format. Confirm RoHS compliance status if environmental regulations apply to the end product. Check for any recent component obsolescence notices from the manufacturer before finalizing procurement plans.

Thermostats - Solid State Selection Notes

Select this component when precise dual-threshold monitoring is required without external components. Consider the SOT-23-6 package size constraints and the open-drain output requirement for interfacing with host logic. Evaluate the power supply voltage range against system availability and ensure the operating temperature range meets environmental demands.

Thermostats - Solid State Part Context

This part belongs to the MAX6505-MAX6508 series of dual-trip temperature switches. These devices integrate temperature sensing and comparison functions into a single compact package. The series offers various factory-programmed thresholds and output configurations to simplify thermal design in space-constrained applications.

Thermostats - Solid State Replacement Considerations

Compatible substitutes include other MAX6505 variants with different trip temperatures (e.g., MAX6505UTP045+T) or the MAX6507/MAX6508 series which may offer push-pull outputs instead of open-drain. Verify pin compatibility and electrical characteristics before substitution.