  • Description:MOD IPM 3PHASE IGBT 1200V 25A
  • Series:-

SKU:545037744e62 Category: Brand:

ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:MOD IPM 3PHASE IGBT 1200V 25A
  • Series:-
  • Mfr:Powerex Inc.
  • Package:Bulk
  • Type:IGBT
  • Configuration:3 Phase
  • Current:25 A
  • Voltage:1.2 kV
  • Voltage - Isolation:2500Vrms
  • Mounting Type:Through Hole
  • Package / Case:36-PowerDIP Module (2.480", 63.00mm)
  • Grade:-
  • Qualification:-

Download product information

PS12017-A

Overview

The PS12017-A is a flat-base insulated Application Specific Intelligent Power Module (ASIPM) manufactured by Mitsubishi Semiconductor. It integrates a three-phase IGBT inverter bridge with dynamic braking capabilities, utilizing third-generation IGBT and diode technologies. The module supports an AC400V class application with a continuous output current of 7.2A rms at 100% load and 10.8A rms for one minute under 150% overload conditions. Key electrical ratings include a collector-emitter voltage of 1200V and a junction temperature range from -20°C to +125°C.

Feature Summary

  • Integrates drive circuits, protection mechanisms, and system control functions within a single insulated package.
  • Features short-circuit protection, under-voltage/over-voltage locking, and over-temperature protection.
  • Provides analogue signal feedback to reproduce actual inverter output phase currents.
  • Includes input interface compatibility with 5V CMOS/TTL standards and shoot-through interlock protection.

Applications

  • Acoustic noise-less 3.0kW/AC400V Class 3 Phase inverters
  • Motor control applications requiring integrated drive and protection
  • Systems utilizing dynamic braking for motor regenerative energy

Procurement Notes

Verify the specific revision status of the datasheet, as the provided documentation indicates preliminary specifications where parametric limits are subject to change. Confirm that the required thermal management solutions align with the specified junction-to-case thermal resistance values. Ensure that the mounting torque adheres strictly to the recommended range of 0.98 to 1.47 N·m to maintain proper insulation and thermal contact integrity.

Selection Notes

Select this module for applications requiring high voltage isolation and integrated intelligent power switching. Consider the 1200V rating for robustness against surge voltages in industrial environments. Evaluate the thermal performance based on the maximum case operating temperature of +100°C. Verify that the control supply voltages match the recommended 15V for driver supplies and 5V for logic interfaces.

Part Context

This component belongs to the family of Application Specific Intelligent Power Modules (ASIPMs). It combines power semiconductor devices with control electronics to simplify inverter design. The flat-base insulated type facilitates direct mounting to heatsinks while providing electrical isolation between the terminals and the base plate.

Replacement Considerations

Public confirmed substitute part numbers are not available in the verified source material.

FAQ

How does the module handle arm shoot-through?

The module includes an input inter-lock sensing circuit that blocks arm shoot-through. If simultaneous low-level inputs are detected for an upper-arm and lower-arm pair, both IGBTs are cut off, and an FO signal is outputted.

What is the function of the CL terminal?

The CL terminal provides a warning signal when the inverter current exceeds the current-limit warning level. This operates on a pulse-by-pulse scheme and resets automatically with the next input signal.

Can the module be used for load current regulation?

No, the short-circuit protection is intended primarily to protect against distraction faults. For load current regulation or overload control, the analogue current output feature or the CL warning feature should be used instead.