The Astrodyne TDI RP135-6-2.2-QD is a single-stage, one-phase power line filter designed for chassis mounting. It features a rated current of 6 A and a capacitance of 2.2 nF. The unit operates at frequencies of 50 Hz and 60 Hz with a voltage rating of 250 VAC. Key electrical specifications include a leakage current of 800 uA. The component complies with UL, CSA, and EN standards.
Verify the specific suffix QD corresponds to the required quick disconnect terminal type for your assembly. Confirm that the 800 uA leakage current aligns with system safety requirements. Ensure chassis mounting dimensions accommodate the physical footprint. Cross-reference the 2.2 nF capacitance value against circuit design constraints to prevent inrush issues.
Select this model when a single-stage solution suffices for the application's attenuation needs. The 6 A rating suits moderate power loads. Compare against the RP135-3-2.2-QD if lower current capacity is acceptable. Consider dual-stage alternatives like the RP220 series if higher attenuation is required. Verify that the quick connect terminals match existing wiring harnesses.
This component belongs to the RP135 series, which offers high-performance single-stage filtration. The series provides various current ratings from 1 A to 60 A. The RP135-6-2.2-QD specifically targets applications needing 6 A handling with standard capacitance values. It serves as a compact solution for basic power line conditioning tasks.
Direct substitutes within the same series include RP135-3-2.2-QD for reduced current or RP135-10-2.2-QD for increased capacity. Ensure terminal type compatibility when swapping models.