RTEN-5020D is listed in the Power Line Filter Modules range at ChipApex. The manufacturer field lists TDK-Lambda. Its product description is LINE FILTER 500VAC/VDC 20A DIN. Review the specifications below when checking this part for your BOM.

Power Line Filter Modules specifications for RTEN-5020D

  • Description:LINE FILTER 500VAC/VDC 20A DIN
  • Series:RTEN
  • Mfr:TDK-Lambda
  • Package:Bulk
  • Filter Type:Three Phase (Delta)
  • Configuration:Single Stage
  • Voltage - Rated DC:500V
  • Voltage - Rated AC:500V
  • Current:20 A
  • Frequency - Operating:-
  • Applications:General Purpose
  • Approval Agency:EN, UL
  • Operating Temperature:-25°C ~ 85°C
  • Mounting Type:DIN Rail
  • Termination Style:Terminal Block
  • Inductance:-
  • Voltage - Rated AC (Phase to Ground/Neutral):-
  • Voltage - Rated AC (Phase to Phase):-

Power Line Filter Modules datasheet and documents for RTEN-5020D

RTEN-5020D

Power Line Filter Modules Overview

The TDK-Lambda RTEN-5020D is a three-phase power line filter designed for DIN rail mounting. It features a rated current of 20A and a rated voltage of 500V AC/DC. The unit provides high dielectric strength with an insulation resistance of at least 100MΩ. It ensures common mode attenuation of 25dB within the 0.5 to 8MHz frequency band and differential mode attenuation of 25dB from 0.2 to 30MHz. The device operates reliably in temperatures ranging from -25°C to +85°C.

Power Line Filter Modules Feature Summary

  • Ultra-thin wire-type design facilitates easy wiring operations and saves space.
  • High versatility suitable for diverse industrial applications.
  • Complies with UL1283 and EN60939 safety standards.

Power Line Filter Modules Applications

  • Telecommunications equipment
  • Industrial automation systems
  • General-purpose power supply noise suppression

Power Line Filter Modules Procurement Notes

Verify that the specific part number matches the required DIN rail mounting style, as standard versions differ. Confirm compliance with local safety certifications such as UL or EN before integration. Ensure the selected leakage current rating is compatible with upstream residual current devices to prevent nuisance tripping during operation.

Power Line Filter Modules Selection Notes

Select this model when DIN rail installation is required for three-phase circuits up to 20A. Compare against the non-DIN version if panel mounting is preferred. Evaluate the specific attenuation requirements against the provided frequency bands. Consider the physical dimensions and weight constraints of the enclosure where the filter will be installed.

Power Line Filter Modules Part Context

This component belongs to the RTEN series of ultra-three-phase power filters manufactured by TDK-Lambda. The series is engineered for compactness and ease of integration into modern electronic systems. The 'D' suffix specifically denotes the DIN rail mounting configuration, distinguishing it from the standard wire-type variant.

Power Line Filter Modules Replacement Considerations

The RTEN-5020 is the direct equivalent without DIN rail mounting. Other models in the RTEN series offer different current ratings but share similar form factors. Verify pinout and terminal compatibility when substituting with other three-phase filters from different manufacturers.

Power Line Filter Modules FAQ

Is this filter suitable for use between a general-purpose inverter and a motor?

No, the product documentation explicitly states that this noise filter cannot be used between a general-purpose inverter and a motor.

What is the maximum leakage current for this component?

The maximum leakage current is 2.5mA at 250V and 5.0mA at 500V.