SE-L140 is listed in the Thermostats - Mechanical range at ChipApex. The manufacturer field lists Selco Products. Its product description is 3/4" DISC THERMOSTAT, 25AMP. Review the specifications below when checking this part for your BOM.
Thermostats - Mechanical specifications for SE-L140
- Description:3/4" DISC THERMOSTAT, 25AMP
- Series:SE T10
- Mfr:Selco Products
- Package:Bulk
- Circuit:-
- Switching Temperature:140°F (60°C)
- Reset Temperature:-
- Current Rating - AC:25A (120V), 25A (240V)
- Current Rating - DC:-
- Tolerance:±7.2°F (±4°C)
- Switching Cycles:100K
- Termination Style:Quick Connect
- Mounting Type:Chassis Mount
- Package / Case:Cylinder with Mounting Flange
Thermostats - Mechanical datasheet and documents for SE-L140
Thermostats - Mechanical Overview
The SE-L140 is a direct-sensing disc thermostat manufactured by Selco Products, designed for high-capacity thermal control in demanding environments. It features a robust bimetallic disc mechanism housed in a cylinder with a mounting flange, utilizing quick connect termination style for secure electrical interfacing. The component operates at a switching temperature of 140°F (60°C) with a tolerance of ±7.2°F (±4°C). It supports AC current ratings of 25A at both 120V and 240V, ensuring reliable performance across standard voltage configurations. The unit is rated for 100,000 switching cycles and withstands 1500 VAC dielectric stress for one minute. Certified to UL and cUL standards, it functions within an operating range from 40°C to 170°C.
Thermostats - Mechanical Feature Summary
- Direct sensing design utilizes a powerful bimetallic disc for higher electrical rating and rapid thermal response.
- Chassis mount construction with a cylinder body and integrated mounting flange for stable installation.
- Certified compliance with UL and cUL safety standards for industrial and commercial reliability.
Thermostats - Mechanical Applications
- HVAC systems requiring high-current thermal regulation
- Industrial applications needing durable disc thermostats
- Equipment utilizing 120/240 VAC power supplies
Thermostats - Mechanical Procurement Notes
When procuring the SE-L140, verify that the specific order matches the manufacturer's part number exactly to ensure correct switching temperature and electrical ratings. Confirm that the quick connect termination style aligns with the wiring harness or terminal block specifications of the target equipment. Ensure the chassis mount configuration fits the available space and mounting surface requirements. Check for any specific packaging variations if bulk quantities are required, as standard packaging may differ from broken-pack quantities. Validate that the application environment stays within the specified operating temperature range of 40°C to 170°C to maintain component integrity and certification validity.
Thermostats - Mechanical Selection Notes
Select the SE-L140 when the application demands a high-current capacity of 25A at 120V or 240V AC. This model is appropriate for systems where direct air stream sensing is preferred over capillary tube sensing for faster reaction times. Consider this part if the physical dimensions of 2 inches length by 1.654 inches width fit the assembly constraints. Verify that the required switching temperature of 140°F (60°C) matches the thermal cutoff or control point of the system. Ensure the inductive load requirements, such as FLA and LRA ratings, fall within the specified limits for the chosen voltage.
Thermostats - Mechanical Part Context
The SE-L140 belongs to the SE Series of disc thermostats produced by Selco Products. This series is characterized by larger physical sizes compared to smaller thermostats, allowing for more powerful bimetallic discs and higher electrical ratings. These components are engineered for durability and consistent performance in continuous duty applications. The SE series includes various models differentiated primarily by their switching temperatures and specific mounting or termination options, catering to a broad spectrum of heating and cooling control needs.
Thermostats - Mechanical Replacement Considerations
Verify that any substitute part maintains the same 140°F (60°C) switching temperature and ±7.2°F tolerance. Ensure the replacement offers identical 25A AC current ratings at 120V and 240V. Confirm that the new component supports SPST/SPDT output types and matches the quick connect termination style. The replacement must also accommodate the cylinder with mounting flange package type and meet the 1500 VAC dielectric rating.
Thermostats - Mechanical FAQ
What is the switching temperature tolerance for the SE-L140?
The switching temperature tolerance is ±7.2°F (±4°C).
Can the SE-L140 handle inductive loads?
Yes, it supports inductive loads with ratings of 10 F.L.A. and 60 L.R.A. at 120 VAC, and 5 F.L.A. and 30 L.R.A. at 240 VAC.
Is the SE-L140 certified for use in North America?
Yes, the component is UL and cUL Listed.
What is the expected lifespan in terms of switching cycles?
The SE-L140 is rated for 100,000 switching cycles.
Explore related parts through Temperature Sensors, Sensors, Transducers, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier