Power Transformers ST3-36B25 product image

ST3-36B25

  • Description:PWR XFMR LAMINATED 2.4VA TH
  • Series:Split Bobbin Plug-In
  • Mfr:Pulse Electronics
  • Package:Bulk

SKU:ST3-36B25 Category: Brand:

ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

ST3-36B25 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Pulse Electronics. Its product description is PWR XFMR LAMINATED 2.4VA TH. Review the specifications below when checking this part for your BOM.

Power Transformers specifications for ST3-36B25

  • Description:PWR XFMR LAMINATED 2.4VA TH
  • Series:Split Bobbin Plug-In
  • Mfr:Pulse Electronics
  • Package:Bulk
  • Type:Laminated Core
  • Voltage - Primary:115V
  • Voltage - Secondary (Full Load):Parallel 18V, Series 36V
  • Current - Output (Max):Parallel 130mA, Series 65mA
  • Primary Winding(s):Single
  • Secondary Winding(s):Dual
  • Center Tap:No
  • Power - Max:2.4VA
  • Mounting Type:Through Hole
  • Termination Style:PC Pin
  • Size / Dimension:35.05mm L x 28.70mm W
  • Height - Seated (Max):30.23mm
  • Voltage - Isolation:2500Vrms
  • Weight:0.25 lb (113.4 g)

Power Transformers datasheet and documents for ST3-36B25

ST3-36B25

Power Transformers Overview

The ST3-36B25 is a low-frequency, open-style laminated power transformer manufactured by Pulse Electronics. It features a split bobbin construction and utilizes a horizontal plug-in mounting configuration for through-hole assembly. The component has a rated power capacity of 2.4 VA. It is designed for general-purpose power supply applications requiring reliable isolation and voltage transformation in electronic circuits.

Power Transformers Feature Summary

  • Open-style laminated core construction
  • Split bobbin winding design
  • Horizontal plug-in mounting format

Power Transformers Applications

  • Low frequency power supply circuits
  • General purpose voltage transformation
  • Electronic equipment isolation

Power Transformers Procurement Notes

Verify the manufacturer designation as Pulse Electronics or its subsidiary entities when sourcing. Confirm the specific package style matches the horizontal plug-in requirement. Ensure the 2.4 VA rating aligns with the target circuit's power demands. Check for RoHS compliance status if environmental regulations apply to the final assembly.

Power Transformers Selection Notes

Select this component for applications requiring a compact, through-hole mounted transformer with a 2.4 VA capacity. The horizontal orientation facilitates specific PCB layout constraints. Verify that the operating frequency range supports the intended low-frequency application requirements before integration into the design.

Power Transformers Part Context

This part belongs to the ST3 series of low-frequency transformers from Pulse Electronics. The series includes various models with different power ratings and pin configurations. The ST3-36B25 specifically denotes the 2.4 VA variant within the horizontal plug-in product line.

Power Transformers Replacement Considerations

Cross-reference with other Pulse Electronics ST3 series parts for similar power ratings. Verify pinout compatibility and physical dimensions against potential substitutes. Consult official distributor databases for equivalent listings.

Buying Guide
Summary

Pulse Electronics ST3-36B25 is typically reviewed in Power Transformers category in power designs where startup behavior, fault handling, and thermal headroom need to stay measurable at the point of load. Key specs include Description (PWR XFMR LAMINATED 2.4VA TH), Mounting (Through Hole), and Packaging (Bulk).

Selection Notes
  • For ST3-36B25, verify the mounting type (Through Hole) fits your manufacturing and inspection workflow.
  • Confirm the supply current (Parallel 130mA, Series 65mA) is acceptable for standby and active operation.
  • Check Primary Winding(s) (Single) against the datasheet conditions and your system-level constraints.
  • Verify Termination Style (PC Pin) matches your requirements and the datasheet test conditions.
Alternates & Substitutions
  • For ST3-36B25, the better choices tend to keep startup, protections, and thermal style close to the original layout assumptions.
  • For ST3-36B25 in Power Transformers, favor alternates that keep startup behavior, protection style, and thermal expectations close to the original design.
  • Alternate decisions stay clearer when must-match attributes are kept distinct from features that are only nice to have.
  • The best second source is usually the one that stays believable at real corners instead of typical values alone.
FAQ

What Size / Dimension does ST3-36B25 have?
35.05mm L x 28.70mm W

What is the Voltage - Primary of ST3-36B25?
115V

Which Voltage - Isolation is listed for ST3-36B25?
2500Vrms

Can you confirm the Center Tap for ST3-36B25?
No

Application Scenarios

Pulse Electronics ST3-36B25 is usually reviewed in Power Transformers designs after the team defines which released constraint would be most expensive to rediscover after build, such as contact stability, source settling, shielding, thermal rise, or service access. On released hardware, teams usually recheck mounting (Through Hole) first. Power-stage choices tend to pay back in validation time by making EMI, thermal headroom, and protection behavior easier to prove. In many systems, stable rails are what keep converters, RF blocks, and processors inside their performance envelope under real loads. In consumer chargers and adapters, startup behavior and fault response influence safety compliance and perceived reliability. In outdoor IoT enclosures, derating and surge resilience matter because supply quality and temperature drift are less controlled. In real deployments, when margins are explicit and measurable, stability tends to hold up better across real deployments.

Compatibility Advice
  • In Pulse Electronics ST3-36B25 integration, with the final enclosure and cabling, validate the same Power Transformers limits around coupling behavior, saturation or insertion loss, and thermal rise that production and service teams can rerun later instead of relying on a bench-only setup. Record the exact load, wiring, and limits so the same evidence can be regenerated during ECO or second-source review.
  • To avoid late rework, validate derating under voltage and ripple current so passives do not run at the edge in continuous duty. Record the exact load, wiring, and limits so the same evidence can be regenerated during ECO or second-source review.
Project Fit
  • Pulse Electronics ST3-36B25 is a practical fit for Power Transformers when the project has a defined accuracy budget and can verify drift and tolerance stack-up in production.
ST3-36B25ST3-36B25

Click on the inquiry