ST4-36B26 is listed in the Power Transformers range at ChipApex. The manufacturer field lists Pulse Electronics. Its product description is PWR XFMR LAMINATED 6VA TH. Review the specifications below when checking this part for your BOM.
Power Transformers specifications for ST4-36B26
- Description:PWR XFMR LAMINATED 6VA TH
- Series:Split Bobbin Plug-In
- Mfr:Pulse Electronics
- Package:Bulk
- Type:Laminated Core
- Voltage - Primary:115V
- Voltage - Secondary (Full Load):Parallel 18V, Series 36V
- Current - Output (Max):Parallel 340mA, Series 170mA
- Primary Winding(s):Single
- Secondary Winding(s):Dual
- Center Tap:No
- Power - Max:6VA
- Mounting Type:Through Hole
- Termination Style:PC Pin
- Size / Dimension:41.40mm L x 33.27mm W
- Height - Seated (Max):33.27mm
- Voltage - Isolation:2500Vrms
- Weight:0.44 lb (199.58 g)
Power Transformers datasheet and documents for ST4-36B26
Power Transformers Overview
The ST4-36B26 is a low-frequency power transformer from Pulse Electronics, designed for horizontal plug-in mounting. It features a laminated core and split bobbin construction with vacuum encapsulation for improved heat dissipation. The unit provides 6VA capacity with a 36V center-tapped secondary at 0.17A (or 18V at 0.34A). It supports leading vendors' silicon for battery management systems (BMS) and energy storage solutions (ESS), delivering up to 2W of power across high withstand voltage applications.
Power Transformers Feature Summary
- Vacuum encapsulation for enhanced thermal performance
- Split bobbin design for isolation integrity
- Laminated core construction for efficiency
Power Transformers Applications
- Battery Management Systems (BMS)
- Energy Storage Solutions (ESS)
- Low frequency power conversion
Power Transformers Procurement Notes
Verify the exact part number suffix against official Pulse Electronics documentation to ensure correct electrical specifications and pinout configuration. Confirm that the vacuum encapsulated laminated design meets your specific thermal and isolation requirements for BMS or ESS applications before finalizing procurement.
Power Transformers Selection Notes
Select this component when a 6VA horizontal plug-in transformer is required for BMS or ESS circuits. Ensure compatibility with 50/60Hz operation and verify that the 36V center-tapped secondary current rating aligns with the load requirements. The vacuum encapsulation offers compactness compared to non-encapsulated alternatives.
Power Transformers Part Context
This component belongs to the LT Split Bobbin Plug-in Series by Pulse Electronics Power. It is engineered for low-frequency applications requiring robust isolation and efficient heat dissipation through its vacuum encapsulated laminated structure. The series supports various secondary configurations for diverse power supply needs.
Power Transformers Replacement Considerations
Check datasheets for equivalent transformers in the same series with matching VA ratings and secondary voltage/current specifications. Verify physical footprint compatibility for horizontal plug-in mounting and ensure insulation class ratings meet system safety standards.
Explore related parts through Transformers, all product categories, ChipApex homepage.
Buying Guide
Pulse Electronics ST4-36B26 is usually screened in Power Transformers category when loop stability, transient response, and released protection limits must hold under the same wiring and load steps the product will see. Key specs include Description (PWR XFMR LAMINATED 6VA TH), Mounting (Through Hole), and Packaging (Bulk).
- For ST4-36B26, verify Weight (0.44 lb (199.58 g)) and compare it against your reference design limits.
- Make sure the mounting type (Through Hole) matches how the part will be installed and inspected.
- Ensure the supply current (Parallel 340mA, Series 170mA) is acceptable for battery life and thermal limits.
- Make sure Voltage - Primary (115V) aligns with your design targets and verification plan.
- For ST4-36B26, the better choices tend to keep startup, protections, and thermal style close to the original layout assumptions.
- For ST4-36B26 in Power Transformers, favor alternates that keep startup behavior, protection style, and thermal expectations close to the original design.
- The best second source is usually the one that stays believable at real corners instead of typical values alone.
- When several alternates look close for Power Transformers, use power, transformers to decide which option still matches the original application best.
Who is the manufacturer of ST4-36B26?
Pulse Electronics
Any tips for derating and validation for ST4-36B26?
Validate at worst-case temperature and load, confirm thermal headroom, and check protection and startup behavior with margin.
Which Height - Seated (Max) is listed for ST4-36B26?
33.27mm
What Secondary Winding(s) is listed for ST4-36B26?
Dual
Application Scenarios
Selecting Pulse Electronics ST4-36B26 for Power Transformers usually comes down to the constraints that still matter after build: fit, limits, recovery behavior, and testability on the real hardware. On released hardware, teams usually recheck mounting (Through Hole) first. Power-stage choices tend to pay back in validation time by making EMI, thermal headroom, and protection behavior easier to prove. In many systems, stable rails are what keep converters, RF blocks, and processors inside their performance envelope under real loads. In medical equipment, power integrity and fault behavior are validated to protect both measurements and safety requirements over long duty cycles. In consumer chargers and adapters, startup behavior and fault response influence safety compliance and perceived reliability. The goal is to keep the critical electrical, thermal, and mechanical checks tied to something the team can verify again later.
Compatibility Advice
- In Pulse Electronics ST4-36B26 integration, on the assembled PCB, validate parasitics and resonance in the real layout so high-frequency behavior does not create surprises in EMI and stability. This avoids one-off tuning in production.
- Where substitutions are likely, confirm that substitutions preserve dielectric or core material behavior because that often changes drift and loss more than the nominal value. This avoids one-off tuning in production.
Project Fit
- Pulse Electronics ST4-36B26 is a practical fit for Power Transformers when the team can validate derating, self-heating, and frequency behavior on the assembled system.
- Pulse Electronics ST4-36B26 is more likely to create avoidable rework in Power Transformers projects when frequency behavior and parasitics are not measured, so stability and noise outcomes are uncertain because validation would rely on assumptions that cannot be re-tested later.
ChipApex | Global Electronic Components Supplier