XY2CD111 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CD111
- Description:CABLE PULL SWITCH 1NC 3A 240V
- Series:XY2CD
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NO/NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:6m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CD111
Cable Pull Switches Overview
The Telemecanique Sensors XY2CD111 is a cable pull switch belonging to the XY2CD series. It features a single normally open contact configuration and supports both on-off and off-on switching functions. The device has a current rating of 3A for AC applications and 270mA for DC applications, with voltage ratings of 240V AC and 250V DC. The maximum supported cable length is 6 meters. The unit includes an integrated push button emergency stop switch mechanism.
Cable Pull Switches Feature Summary
- Integrated push button emergency stop switch
- Single normally open contact configuration
- Supports on-off and off-on switching functions
Cable Pull Switches Applications
- Emergency stop systems in industrial machinery
- Safety interlocking for conveyor belts
- Cable tension monitoring in automated production lines
Cable Pull Switches Procurement Notes
Verify that the specific application requires a single normally open (NO) contact configuration, as this model differs from variants offering multiple contacts or different actuation types. Confirm that the operational voltage does not exceed 240V AC or 250V DC and that the load current remains within the 3A AC or 270mA DC limits. Ensure the installation environment accommodates the specified maximum cable length of 6 meters. Check for compatibility with existing mounting hardware and wiring interfaces suitable for the XY2CD series. Review local safety regulations regarding emergency stop device integration to ensure compliance with industry standards.
Cable Pull Switches Selection Notes
Select this component when a dedicated emergency stop function combined with cable pull activation is required. The single NO contact design suits simple circuit interruption needs. Consider the 6-meter cable limit for layout planning. Evaluate if the 3A AC rating meets the control circuit requirements. Compare against models with additional contacts if complex logic sequencing is necessary. Assess environmental conditions to ensure the switch housing provides adequate protection for the intended installation location.
Cable Pull Switches Part Context
This cable pull switch is part of the broader XY2CD series by Telemecanique Sensors, designed for safety applications. The brand specializes in sensors and switches for industrial automation, emphasizing reliability and safety compliance. The XY2CD series focuses on providing robust emergency stopping solutions for heavy machinery and material handling equipment. Products in this line are engineered to meet stringent international safety standards, ensuring consistent performance in demanding operational environments.
Cable Pull Switches Replacement Considerations
Consult official Telemecanique Sensors documentation for direct cross-reference part numbers. Verify contact configuration and voltage ratings match exactly. Ensure mechanical dimensions and mounting styles are compatible with existing infrastructure. Do not assume functional equivalence between different series without explicit manufacturer confirmation.
Explore related parts through Switches, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier