XY2CE2C290 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CE2C290
- Description:CABLE PULL SWITCH 1NC 3A 240V
- Series:XY2CE
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NO/NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:90m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CE2C290
Cable Pull Switches Overview
The Telemecanique Sensors XY2CE2C290 is a latching emergency stop rope pull switch from the XY2C series, designed for simple reset via a flush push-button. It features a red housing (RAL 3000) with a Zamak body and stainless steel cover. The device includes one trigger cable with a maximum length of 90 meters and utilizes screw clamp terminals for connections. Electrical ratings include a rated operational current of 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13, with a rated insulation voltage of 500 V. It offers IP66 protection, operates within -40°C to 70°C, and provides safety levels up to PL e, Category 4, or SIL 3 when used with appropriate monitoring systems.
Cable Pull Switches Feature Summary
- Latching emergency stop functionality with simple reset by a flush boot-mounted push-button.
- Positive opening contact operation compliant with EN/IEC 60947-5-1 standards.
- High mechanical durability rated at 60,000 cycles with a B10d value of 300,000 over a 20-year lifetime.
- Robust construction featuring a Zamak body, stainless steel cover, and nitril bellow material.
Cable Pull Switches Applications
- Emergency stop systems in industrial machinery requiring certified safety switches.
- Conveyor belt systems where continuous perimeter monitoring is necessary.
- Automated production lines needing reliable latching safety interventions.
- Heavy-duty equipment operating in environments requiring IP66 protection.
Cable Pull Switches Procurement Notes
Verify that the application requires a latching type with simple reset capabilities, as this model does not support automatic or complex reset mechanisms. Confirm that the monitoring system utilized can achieve the specified safety performance levels (PL e, Category 4, or SIL 3), as these ratings depend on correct wiring and external logic. Ensure the trigger cable length does not exceed the maximum supported span of 90 meters. Check environmental conditions to confirm compatibility with the -40°C to 70°C operating range and IP66 ingress protection requirements. Validate terminal torque specifications (0.8–1.2 N.m) during installation to maintain electrical integrity.
Cable Pull Switches Selection Notes
Select the XY2CE2C290 when a latching emergency stop solution with a simple manual reset is required. This model is suitable for applications demanding high safety integrity, reaching PL e, Category 4, or SIL 3 with proper system design. Choose this unit if the environment necessitates robust materials like Zamak and stainless steel, along with IP66 protection. Consider this part for installations where a single trigger cable up to 90 meters is sufficient. Verify that the 1 NC + 1 NO contact configuration aligns with the control circuit requirements.
Cable Pull Switches Part Context
The XY2CE2C290 belongs to the Telemecanique Emergency stop rope pull switches XY2C range. This series is engineered for critical safety applications, providing reliable emergency stopping functions. The product adheres to major international standards including EN/IEC 60947-5-5, UL 508, and CSA C22.2 No 14. It is part of a broader portfolio of safety sensors and switches designed to meet stringent machinery directives and workplace safety regulations.
Cable Pull Switches Replacement Considerations
No direct substitute part numbers are documented in the provided source material.
Cable Pull Switches FAQ
What is the maximum trigger cable length supported by this switch?
The maximum trigger cable length is 90 meters (295.28 ft).
How is the reset mechanism configured for this model?
It uses a simple reset method via a flush boot-mounted push-button.
What safety performance levels can be achieved with this device?
It can reach Performance Level e (PL e), Category 4, or SIL 3 when used with an appropriate monitoring system and correctly wired.
Explore related parts through Switches, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier