XY2CE3A020 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CE3A020
- Description:CABLE PULL SWITCH 1NC 3A 240V
- Series:XY2CE
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NO/NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:50m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CE3A020
Cable Pull Switches Overview
The Telemecanique Sensors XY2CE3A020 is a latching emergency stop rope pull switch from the XY2C series. It features a Zamak body with a stainless steel cover and blue housing. The device provides 1 NC and 1 NO snap action contacts via screw clamp terminals (0.5...2 x 1.5 mm²). Rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13, with a conventional enclosed thermal current of 10 A. Insulation voltage is 500 V, impulse withstand is 6 kV. It supports a trigger cable up to 50 m, has an IP66 rating, operates between -25°C and 70°C, and offers 60,000 mechanical cycles.
Cable Pull Switches Feature Summary
- Latching emergency stop functionality with positive opening contact operation compliant with EN/IEC 60947-5-1.
- Robust construction utilizing a Zamak body and stainless steel cover for durability in industrial environments.
- High protection rating of IP66 against dust and water ingress, suitable for harsh conditions.
- Integrated screw clamp terminal connections supporting specified wire cross-sections.
Cable Pull Switches Applications
- Emergency stop systems for conveyor belts and material handling equipment.
- Safety monitoring on machinery requiring manual cable pull activation.
- Industrial assembly lines and automated production units.
- Heavy-duty manufacturing environments subject to vibration and shock.
Cable Pull Switches Procurement Notes
Verify that the application requires a latching mechanism, as this unit does not reset automatically and must be manually reset after activation. Confirm that the required trigger cable length does not exceed the maximum supported distance of 50 meters. Ensure the control circuit voltage aligns with the rated operational currents: 3 A at 240 V AC or 0.27 A at 250 V DC. Check that the installation environment temperature remains within the -25°C to 70°C operating range. Verify compatibility with existing cable support spacing, which should not exceed 5 meters to maintain proper tension and function.
Cable Pull Switches Selection Notes
Select the XY2CE3A020 when a latching emergency stop response is mandatory rather than a momentary return-to-normal configuration. This model is appropriate for applications where the safety circuit must remain open until a deliberate manual reset occurs. Consider the IP66 rating if the installation location is exposed to dust or washdown procedures. Evaluate the 1 NC + 1 NO contact configuration against the specific logic requirements of the safety relay or PLC input. The robust metal housing makes it suitable for high-vibration areas where plastic housings might fail prematurely.
Cable Pull Switches Part Context
This component belongs to the Telemecanique Sensors XY2C range of emergency stop rope pull switches. The XY2CE designation specifically identifies the latching variant within this family. The product line is designed for industrial safety applications involving moving machinery. It complements other safety devices such as limit switches and push buttons within Schneider Electric's automation portfolio. The series adheres to international standards including EN/IEC 60947-5-1 and CSA certifications, ensuring global compliance for safety-critical installations.
Cable Pull Switches Replacement Considerations
Direct replacement requires another latching emergency stop rope pull switch with identical contact configuration (1 NC + 1 NO) and mounting dimensions. Verify that any substitute part maintains the same IP66 protection level and operates within the -25°C to 70°C temperature range. Ensure the new unit supports the same terminal type and wire gauge specifications. Check if the alternative model also requires manual resetting after activation. Confirm that the replacement meets the same regulatory standards, such as EN/IEC 60947-5-1 and CSA, for the specific jurisdiction of use.
Cable Pull Switches FAQ
Does the XY2CE3A020 reset automatically after the cable is pulled?
No, this is a latching emergency stop switch. It requires a manual reset procedure to restore the contacts to their normal state after activation.
What is the maximum length of the trigger cable supported by this switch?
The maximum trigger cable length is 50 meters (164.04 ft).
Can this switch be used in wet or dusty environments?
Yes, the switch has an IP66 rating, providing complete protection against dust and resistance to powerful water jets, making it suitable for harsh industrial environments.