  • Description:CABLE PULL SWITCH 1NC 3A 240V
  • Series:XY2CE
  • Mfr:Telemecanique Sensors
  • Package:Box

SKU:XY2CE5A296 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

XY2CE5A296 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.

Cable Pull Switches specifications for XY2CE5A296

  • Description:CABLE PULL SWITCH 1NC 3A 240V
  • Series:XY2CE
  • Mfr:Telemecanique Sensors
  • Package:Box
  • Circuit:DPST-NO/NC
  • Switch Function:On-Off, Off-On
  • Current Rating (Amps):3A (AC), 270mA (DC)
  • Voltage Rating - AC:240V
  • Voltage Rating - DC:250V
  • Maximum Cable Length:50m
  • Features:Push Button Emergency Stop Switch
  • pa_operating-force:
  • pa_ingress-protection:
  • pa_operating-temperature:

Cable Pull Switches datasheet and documents for XY2CE5A296

XY2CE5A296

Cable Pull Switches Overview

The Telemecanique Sensors XY2CE5A296 is a latching emergency stop rope pull switch from the XY2C series. It features a blue housing with a Zamak body and stainless steel cover. The device includes one normally closed (NC) and one normally open (NO) snap-action contact, rated for 3 A at 240 V AC or 0.27 A at 250 V DC. It supports a trigger cable length up to 50 m with support spacing of 5 m. Electrical ratings include a rated insulation voltage of 500 V and impulse withstand voltage of 6 kV. Mechanical durability is specified at 60,000 cycles. Operating temperature ranges from -25°C to 70°C, with an IP66 protection rating.

Cable Pull Switches Feature Summary

  • Latching emergency stop functionality with simple reset by flush push button
  • Positive opening contacts compliant with EN/IEC 60947-5-1 standards
  • Robust construction featuring a Zamak body and stainless steel cover
  • High mechanical durability rated for 60,000 operational cycles

Cable Pull Switches Applications

  • Emergency stop systems for industrial machinery
  • Safety control for conveyor belt systems
  • Material handling equipment safety circuits
  • Automated production line emergency shutdowns

Cable Pull Switches Procurement Notes

Verify that the specific application requires a latching rope pull switch rather than a non-latching variant within the XY2C range. Confirm that the required trigger cable length does not exceed the maximum supported distance of 50 meters. Ensure that the installation environment falls within the specified operating temperature range of -25°C to 70°C. Check compatibility with existing control circuit voltages against the rated operational current limits of 3 A AC or 0.27 A DC. Review local safety regulations regarding positive opening contacts and IP66 ingress protection requirements before finalizing procurement.

Cable Pull Switches Selection Notes

Select this model when a latching emergency stop mechanism is mandatory for safety compliance. Choose based on the need for a single reset method via a flush push button. Consider the physical dimensions and mounting requirements for the Zamak and stainless steel housing. Evaluate the electrical load requirements to ensure they align with the 3 A AC or 0.27 A DC contact ratings. Assess environmental conditions to confirm suitability for the IP66 rating and vibration resistance specifications.

Cable Pull Switches Part Context

The XY2CE5A296 belongs to the Telemecanique XY2C series of emergency stop rope pull switches. This series is designed for critical safety applications where immediate machine shutdown is necessary. The product line emphasizes reliability through positive opening contacts and robust mechanical construction. It integrates into broader industrial safety architectures, often complemented by other sensors and limit switches from the same manufacturer to create comprehensive protection systems for heavy machinery and automated processes.

Cable Pull Switches Replacement Considerations

Public confirmed substitute part numbers are not available in the provided documentation. Verify cross-compatibility with existing wiring terminals and cable entry configurations if considering alternative models. Ensure any replacement maintains the same latching functionality and reset mechanism type.

Cable Pull Switches FAQ

What is the reset mechanism for this switch?

The switch utilizes a simple reset by flush push button.

What is the maximum trigger cable length?

The maximum trigger cable length is 50 meters (164.04 ft).

Does this switch have positive opening contacts?

Yes, it features positive opening contacts compliant with EN/IEC 60947-5-1.