Cable Pull Switches XY2CE6A270 product image

XY2CE6A270

$415.00
  • Description:CABLE PULL SWITCH 2NC 3A 240V
  • Series:XY2C
  • Mfr:Telemecanique Sensors
  • Package:Box

SKU:XY2CE6A270 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

XY2CE6A270 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 3A 240V. Review the specifications below when checking this part for your BOM.

Cable Pull Switches specifications for XY2CE6A270

  • Description:CABLE PULL SWITCH 2NC 3A 240V
  • Series:XY2C
  • Mfr:Telemecanique Sensors
  • Package:Box
  • Circuit:DPST-NC
  • Switch Function:On-Off
  • Current Rating (Amps):3A (AC), 270mA (DC)
  • Voltage Rating - AC:240V
  • Voltage Rating - DC:250V
  • Maximum Cable Length:70m
  • Features:-
  • pa_operating-force:
  • pa_ingress-protection:
  • pa_operating-temperature:

Cable Pull Switches datasheet and documents for XY2CE6A270

XY2CE6A270

Cable Pull Switches Overview

The XY2CE6A270 is a latching emergency stop rope pull switch from the Telemecanique XY2C range. It features a red RAL 3000 housing with Zamak body and stainless steel cover, reset by a booted push-button. The device includes two normally closed snap-action contacts. Rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13, with a conventional enclosed thermal current of 10 A. Rated insulation voltage is 500 V, impulse withstand voltage is 6 kV. Mechanical durability is 60000 cycles. Trigger cable maximum length is 70 m (or 100 m for 2 cables). IP protection is IP66. Safety levels include PL e, Category 4, and SIL 3. B10d is 300000 over 20 years.

Cable Pull Switches Feature Summary

  • Latching emergency stop functionality with simple reset via a booted push-button
  • Robust construction using Zamak body and stainless steel cover
  • High safety reliability reaching PL e, Category 4, and SIL 3 with appropriate monitoring
  • Snap action contact operation for positive opening

Cable Pull Switches Applications

  • Emergency stop systems on conveyor belts
  • Safety control in industrial machinery
  • Automated material handling equipment

Cable Pull Switches Procurement Notes

Verify that the application requires a latching type with simple reset by flush push-button. Confirm the trigger cable length does not exceed 70 m for single cable or 100 m for dual cable configurations. Ensure the monitoring system supports the required safety level (PL e, Category 4, or SIL 3). Check terminal compatibility for screw clamp connections accepting 0.5 to 1.5 mm² conductors. Validate ambient temperature requirements fall within -25°C to 70°C.

Cable Pull Switches Selection Notes

Select this model when a latching emergency stop switch is needed for long-distance cable pull applications. Consider the IP66 rating for environments requiring protection against dust and water jets. Evaluate the mechanical durability of 60000 cycles against expected operational frequency. Compare the 3 A AC-15 rating with load requirements. Assess the need for positive opening contacts and compliance with EN/IEC 60947-5-5 standards.

Cable Pull Switches Part Context

The XY2CE6A270 belongs to the Telemecanique XY2C series of emergency stop rope pull switches. This series provides comprehensive safety solutions for industrial machinery. The product line includes various models with different reset mechanisms and cable lengths. The XY2C series is designed to meet international safety standards including EN/ISO 13850 and EN/IEC 60947-5-5. It is part of Schneider Electric's broader portfolio of machine safety components.

Cable Pull Switches Replacement Considerations

No public confirmed substitute part numbers are available in the source documentation.

Cable Pull Switches FAQ

What is the maximum trigger cable length?

The maximum trigger cable length is 70 m for a single cable configuration or 100 m for a dual cable configuration.

How is the switch reset?

The switch is reset by a booted push-button.

What safety levels can be achieved?

With an appropriate monitoring system and correct wiring, it can reach PL e, Category 4, and SIL 3.

XY2CE6A270XY2CE6A270
$415.00