XY2CE6A296 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CE6A296
- Description:CABLE PULL SWITCH 2NC 3A 240V
- Series:XY2CE
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:4PST-2NO/2NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:70m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CE6A296
Cable Pull Switches Overview
The Telemecanique Sensors XY2CE6A296 is a latching emergency stop rope pull switch from the XY2C range, featuring simple reset by flush push button. It has a red RAL 3000 housing with Zamak body and stainless steel cover. The device includes 2 x (1 NC + 1 NO) contacts with slow-break operation and positive opening. Rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13. Conventional enclosed thermal current is 10 A, with rated insulation voltage of 500 V. Mechanical durability is 60000 cycles, and B10d is 300000 over a 20-year lifetime. IP66 protection, operating temperature -25…70 °C, vibration resistance 10 gn, shock resistance 50 gn.
Cable Pull Switches Feature Summary
- Latching emergency stop functionality with simple reset via booted push-button
- Positive opening contact mechanism ensuring safe disconnection
- Robust construction with Zamak body and stainless steel cover for harsh environments
- High safety integrity reaching PL e, Category 4, and SIL 3
Cable Pull Switches Applications
- Emergency stop systems in industrial machinery
- Conveyor belt safety controls
- Automated production lines requiring rope pull activation
- Heavy material handling equipment
Cable Pull Switches Procurement Notes
Verify that the application requires a latching rope pull switch with simple reset capability. Confirm compatibility with existing monitoring systems to achieve required PL e, Category 4, or SIL 3 ratings as per EN/ISO 13849-1 and EN/IEC 61508. Ensure trigger cable length does not exceed 70 m for single cable or 100 m for dual cable configurations. Check terminal specifications: screw clamp terminals accept 1 x 0.5...2 x 1.5 mm² conductors with tightening torque of 0.8…1.2 N.m. Verify environmental conditions are within -25…70 °C operating range and IP66 protection is sufficient. Confirm short-circuit protection requirements match 10 A cartridge fuse gG specification.
Cable Pull Switches Selection Notes
Select this model when a latching emergency stop function is mandatory with manual reset via push-button. Choose based on required safety level: PL e, Category 4, or SIL 3 achievable with proper wiring and monitoring. Consider mechanical durability of 60000 cycles and B10d of 300000 for long-life applications. Evaluate ambient conditions against -25…70 °C operating range and IP66 rating. Assess installation constraints including cable entry options (3 tapped entries Pg 13.5) and connection type (screw clamp). Compare with non-latching variants if continuous monitoring without latching is preferred.
Cable Pull Switches Part Context
The XY2CE6A296 belongs to the Telemecanique XY2C series of emergency stop rope pull switches, designed for industrial safety applications. This series provides reliable emergency stopping mechanisms through tensioned trigger cables. The product complies with EN/IEC 60947-5-5 and EN/IEC 60947-5-1 standards, supporting global regulatory requirements including CE, UL, CSA, and CCC certifications. It integrates into machinery safeguarding systems where rapid shutdown is critical. The design emphasizes durability and safety performance, suitable for demanding environments with high vibration and shock resistance.
Cable Pull Switches Replacement Considerations
No direct substitute part numbers are documented in the provided datasheet. For equivalent functionality, consult Telemecanique Sensors official documentation for updated models within the XY2C series or compatible emergency stop rope pull switches from Schneider Electric. Verify that any replacement maintains identical safety ratings (PL e, Category 4, SIL 3), contact configuration (2 x 1 NC + 1 NO), reset method (simple reset by flush push button), and environmental specifications (IP66, -25…70 °C). Cross-reference terminal types, cable entry options, and mounting dimensions to ensure compatibility with existing installations.
Cable Pull Switches FAQ
What is the maximum trigger cable length supported?
The maximum trigger cable length is 70 m for a single cable configuration or 100 m for a dual cable setup.
How many contacts does the XY2CE6A296 have?
It features 2 x (1 NC + 1 NO) contacts with slow-break operation and positive opening.
What safety levels can be achieved with this switch?
With appropriate monitoring system and correct wiring, it can reach PL = e (EN/ISO 13849-1), Category 4 (EN/ISO 13849-1), and SIL 3 (EN/IEC 61508).
Explore related parts through Switches, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier