Cable Pull Switches XY2CEDC297 product image

XY2CEDC297

$674.70
  • Description:CABLE PULL SWITCH 2NC 3A 240V
  • Series:XY2CED
  • Mfr:Telemecanique Sensors
  • Package:Box

SKU:XY2CEDC297 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

XY2CEDC297 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 3A 240V. Review the specifications below when checking this part for your BOM.

Cable Pull Switches specifications for XY2CEDC297

  • Description:CABLE PULL SWITCH 2NC 3A 240V
  • Series:XY2CED
  • Mfr:Telemecanique Sensors
  • Package:Box
  • Circuit:4PST-2NO/2NC
  • Switch Function:On-Off, Off-On
  • Current Rating (Amps):3A (AC), 270mA (DC)
  • Voltage Rating - AC:240V
  • Voltage Rating - DC:250V
  • Maximum Cable Length:100m
  • Features:Push Button Emergency Stop Switch
  • pa_operating-force:
  • pa_ingress-protection:
  • pa_operating-temperature:

Cable Pull Switches datasheet and documents for XY2CEDC297

XY2CEDC297

Cable Pull Switches Overview

The Telemecanique Sensors XY2CEDC297 is a dual emergency stop rope pull switch from the XY2C series. It features a Zamak body with a stainless steel cover and red RAL 3000 housing. The device provides two contact sets, each comprising one normally closed (NC) and one normally open (NO) contact, utilizing slow-break operation. Rated operational current is 3 A at 240 V AC and 0.27 A at 250 V DC. It supports trigger cables up to 100 m in length on both right-hand and left-hand anchor points. The unit includes a boot-style reset mechanism and a yellow pilot light for local signaling. It offers IP66 protection and achieves safety levels of PL e, Category 4, or SIL 3 when used with appropriate monitoring systems.

Cable Pull Switches Feature Summary

  • Dual emergency stop functionality with independent cable anchor points on both sides
  • Integrated yellow pilot light for visual status indication
  • Slow-break contact operation ensuring positive opening compliance
  • High mechanical durability rated at 60,000 cycles

Cable Pull Switches Applications

  • Emergency shutdown systems for industrial machinery
  • Safety interlocking for conveyor belt systems
  • Hazardous area equipment control
  • Automated production line safety circuits

Cable Pull Switches Procurement Notes

Verify that the specific application requires dual cable pull capability rather than single-ended operation. Confirm that the required safety integrity level (SIL 3 or PL e) can be achieved by integrating this switch with a compatible safety relay or monitoring system, as these ratings depend on correct wiring and external circuit design. Ensure the installation environment does not exceed the specified temperature range of -40°C to 70°C. Check that the mounting configuration allows for the necessary clearance and support distances between cable anchors. Validate that the 3 A contact rating aligns with the control circuit loads to prevent premature wear.

Cable Pull Switches Selection Notes

Select this model when dual-sided cable access is necessary for emergency stopping across extended machinery lengths. The XY2CEDC297 is suitable for applications requiring high safety categories (Category 4 / SIL 3) provided the overall system architecture meets EN/ISO 13849-1 standards. Consider the IP66 rating for environments exposed to dust and water jets. The inclusion of a pilot light simplifies troubleshooting by providing immediate visual feedback on the switch state. Evaluate the 60,000-cycle mechanical life against the expected operational frequency of the safety circuit.

Cable Pull Switches Part Context

This component belongs to the Telemecanique XY2C series of emergency stop rope pull switches, designed for industrial safety applications. The series emphasizes robust construction with Zamak bodies and stainless steel covers to withstand harsh environments. The dual configuration distinguishes it from standard single-cable models, allowing for continuous cable runs anchored at both ends. This design facilitates comprehensive coverage for long linear assets such as conveyors or presses, ensuring that activation can occur from any point along the protected perimeter.

Cable Pull Switches Replacement Considerations

Direct replacement within the same series requires verifying compatibility with existing mounting brackets and cable tensioners. Models like XY2CEDC297 are part of a broader ecosystem; ensure that any substitute maintains the same contact configuration (2x 1NC + 1NO) and voltage ratings. Cross-referencing with older XY2C variants may require checking terminal block dimensions and tightening torque specifications (0.8–1.2 N.m). Always confirm that the replacement unit supports the required safety certification levels for the specific machinery directive compliance.

Cable Pull Switches FAQ

What is the maximum trigger cable length supported by this switch?

The switch supports a maximum trigger cable length of 100 meters (328.08 ft) for each side.

How is the reset mechanism operated?

The switch is reset using a booted push-button located on the housing.

What safety performance levels can this device achieve?

With an appropriate monitoring system and correct wiring, it can reach Performance Level e (PL e), Category 4 per EN/ISO 13849-1, or SIL 3 per EN/IEC 61508.

XY2CEDC297XY2CEDC297
$674.70