XY2CH13150H7 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CH13150H7
- Description:CABLE PULL SWITCH 1NC 3A 240V
- Series:-
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NO/NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:30m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CH13150H7
Cable Pull Switches Overview
The Telemecanique Sensors XY2CH13150H7 is a latching emergency stop rope pull switch from the XY2C/XY2CH series. It features a Zamak body with a stainless steel cover and red housing (RAL 3000). The device includes one normally closed (NC) and one normally open (NO) contact with slow-break operation, reset via a flush push-button. Rated operational current is 3 A at 240 V AC or 0.27 A at 250 V DC. It supports a trigger cable length up to 30 m, offers IP65 protection, and operates within -25°C to 70°C. Mechanical durability is rated at 800,000 cycles.
Cable Pull Switches Feature Summary
- Provides positive opening contacts compliant with EN/IEC 60947-5-1 for reliable emergency stopping.
- Achieves high safety integrity levels including PL e, Category 4, and SIL 3 when used with appropriate monitoring systems.
- Features a robust Zamak and stainless steel construction designed for harsh industrial environments.
- Includes screw clamp terminals for secure electrical connections with specified tightening torque.
Cable Pull Switches Applications
- Emergency stop systems for conveyor belts
- Safety interlocking on machinery guards
- Industrial automation equipment requiring manual reset
Cable Pull Switches Procurement Notes
Verify that the specific application requires a latching type with flush push-button reset, as opposed to non-latching variants. Confirm the required trigger cable length does not exceed the 30 m maximum supported by this model. Ensure the installation environment falls within the specified operating temperature range of -25°C to 70°C. Check if the system design necessitates the specific safety level (PL e, Cat 4, SIL 3) provided by this component when integrated with compatible monitoring relays. Validate that the 1 NC + 1 NO contact configuration meets the control circuit requirements.
Cable Pull Switches Selection Notes
Select this model when a latching emergency stop function is mandatory, requiring manual intervention to restore operation after a trip event. Choose the XY2CH13150H7 over non-latching alternatives if process safety protocols demand that the machine remains stopped until explicitly reset by an authorized operator. Consider the IP65 rating for applications involving washdowns or dusty conditions. Evaluate the mechanical durability of 800,000 cycles against expected maintenance intervals. Ensure compatibility with existing wiring standards using the ISO n°1 terminal descriptions.
Cable Pull Switches Part Context
This component belongs to the Telemecanique Sensors XY2C and XY2CH family of emergency stop rope pull switches. These devices are engineered for industrial safety applications where immediate cessation of hazardous motion is critical. The series distinguishes itself through certified safety performance metrics and robust physical construction. Unlike standard limit switches, these units are specifically designed to interface with safety-rated control systems to ensure compliance with machinery directives and international safety standards.
Cable Pull Switches Replacement Considerations
When replacing older models, verify that the new unit maintains the same contact configuration (1 NC + 1 NO) and mounting dimensions. Ensure the replacement supports the same safety integrity levels required by the original system design. Check for compatibility with existing trigger cables and anchor points. Confirm that the reset mechanism type (flush push-button) matches the operational workflow of the facility.
Cable Pull Switches FAQ
What is the method for resetting the switch after activation?
The switch is reset using a flush push-button located on the device body.
Does this switch support automatic recovery?
No, it is a latching emergency stop switch that requires manual reset via the flush push-button; it does not auto-reset.
What is the maximum trigger cable length supported?
The maximum trigger cable length is 30 meters (98.43 ft).