XY2CH13170H7 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CH13170H7
- Description:CABLE PULL SWITCH 2NC 3A 240V
- Series:-
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NC
- Switch Function:On-Mom
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:30m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CH13170H7
Cable Pull Switches Overview
The Telemecanique Sensors XY2CH13170H7 is a latching emergency stop rope pull switch from the XY2C series. It features a Zamak body with a stainless steel cover and red housing (RAL 3000). The device utilizes two normally closed contacts with slow-break operation, rated for 3 A at 240 V AC or 0.27 A at 250 V DC. It supports a trigger cable length up to 30 m and offers IP65 protection. Safety performance includes PL e per EN/ISO 13849-1, Category 4, and SIL 3 per EN/IEC 61508. Mechanical durability is rated at 8,000,000 cycles.
Cable Pull Switches Feature Summary
- Latching emergency stop functionality with flush push-button reset mechanism
- Positive opening contact design compliant with safety standards
- Robust construction using Zamak body and stainless steel cover
- High mechanical endurance rated for 8,000,000 operational cycles
Cable Pull Switches Applications
- Emergency shutdown of industrial machinery
- Safety interlocking in conveyor systems
- Protection mechanisms in automated production lines
Cable Pull Switches Procurement Notes
Verify that the specific application requires a latching configuration rather than a non-latching variant. Confirm the required cable length does not exceed the 30 m maximum specification. Ensure the monitoring system is correctly wired to achieve the stated safety levels (PL e, Category 4, SIL 3). Check compatibility with existing control voltage ratings (240 V AC / 250 V DC) before installation. Review local regulatory requirements regarding EN/IEC 60947-5-5 compliance for your region.
Cable Pull Switches Selection Notes
Select this model when a latching emergency stop response is mandatory to prevent automatic restart after a trip event. Choose the XY2CH13170H7 if the environment demands high corrosion resistance provided by the stainless steel cover. Consider this unit for applications requiring certified safety integrity levels up to SIL 3. Evaluate the need for positive opening contacts to ensure reliable disconnection under fault conditions.
Cable Pull Switches Part Context
This component belongs to the Telemecanique XY2C range of emergency stop rope pull switches. The series provides various configurations for different safety requirements and environmental conditions. The XY2CH designation indicates a latching version with specific contact arrangements. This product line is designed to meet global machinery safety directives including EN/IEC 60204-1.
Cable Pull Switches Replacement Considerations
Public confirmed substitute part numbers are not available in the source documentation.