XY2CH13250TK is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CH13250TK
- Description:CABLE PULL SWITCH 1NC 3A 240V
- Series:XY2CH
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NO/NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:30m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CH13250TK
Cable Pull Switches Overview
The Telemecanique Sensors XY2CH13250TK is a latching emergency stop rope pull switch from the XY2C range. It features a blue Zamak body with a stainless steel cover and IP65 protection. The unit includes one normally closed (NC) and one normally open (NO) contact with slow-break operation, reset via a booted push-button. Rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13. Conventional enclosed thermal current is 10 A, with an insulation voltage of 500 V and impulse withstand voltage of 6 kV. Mechanical durability is 800,000 cycles, and B10d is 4,000,000 over a 20-year lifetime. Trigger cable length reaches 30 m, supported every 5 m.
Cable Pull Switches Feature Summary
- Latching emergency stop functionality with positive opening contacts for safety compliance
- Reset mechanism utilizes a protected booted push-button to prevent accidental reactivation
- Robust construction with Zamak housing and stainless steel cover for corrosive environments
- High mechanical endurance rated at 800,000 cycles with long-term reliability data
Cable Pull Switches Applications
- Emergency stop systems on industrial machinery
- Conveyor belt safety monitoring
- Material handling equipment requiring rapid shutdown
- Automated production lines needing compliant safety interlocks
Cable Pull Switches Procurement Notes
Verify that the specific application environment falls within the operating temperature range of -25°C to 70°C. Confirm that the wiring setup supports the required safety integrity level, as PL e, Category 4, or SIL 3 ratings depend on correct external monitoring system integration. Ensure the trigger cable length does not exceed 30 m without additional support structures spaced at 5 m intervals. Check local regulatory requirements against EN/IEC 60947-5-5 and UL NISD certifications before deployment. Review the California Proposition 65 warning regarding chemical exposure during installation or disposal.
Cable Pull Switches Selection Notes
Select this model when a latching emergency stop function is mandatory rather than momentary release. The XY2CH13250TK is suitable for applications requiring high mechanical durability and resistance to corrosive conditions due to its material composition. Consider the 30 m trigger span and 5 m support spacing for layout planning. Verify compatibility with existing control circuits regarding the 3 A AC and 0.27 A DC current ratings. Ensure the IP65 rating meets environmental protection needs against dust and water jets.
Cable Pull Switches Part Context
This component belongs to the Telemecanique XY2C series of emergency stop rope pull switches. The series is designed for industrial safety applications where reliable manual activation of emergency stops is critical. The XY2CH variant specifically denotes a latching configuration with distinct contact arrangements. Telemecanique Sensors provides these devices as part of a broader portfolio of safety sensors and switches, adhering to international standards such as EN/ISO 13849-1 and EN/IEC 61508 for safety performance evaluation.
Cable Pull Switches Replacement Considerations
Direct replacement requires matching the latching mechanism, contact configuration (1 NC + 1 NO), and mounting dimensions. Verify that any substitute device supports the same safety levels (PL e, Cat 4, SIL 3) and environmental ratings (IP65). Ensure the new unit accommodates the same trigger cable specifications and reset method if booted push-button reset is required. Cross-reference terminal types and tightening torque specifications to maintain electrical connection integrity.
Cable Pull Switches FAQ
What is the maximum trigger cable length supported by this switch?
The maximum trigger cable length is 30 meters.
How is the switch reset after activation?
It is reset using a booted push-button located on the unit.
What safety integrity levels can be achieved with this device?
With appropriate monitoring and wiring, it can reach PL e per EN/ISO 13849-1, Category 4 per EN/ISO 13849-1, and SIL 3 per EN/IEC 61508.
Explore related parts through Switches, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier