XY2CH13253 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CH13253
- Description:CABLE PULL SWITCH 1NC 3A 240V
- Series:XY2CH
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NO/NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:30m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CH13253
Cable Pull Switches Overview
The Telemecanique Sensors XY2CH13253 is a latching emergency stop rope pull switch from the XY2CH series. It features a Zamak body with a stainless steel cover and a red RAL 3000 housing. The device includes one normally closed (NC) and one normally open (NO) contact with slow-break operation, reset via a booted push-button, and a yellow pilot light powered by 24 V AC/DC. Rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13. Conventional enclosed thermal current is 10 A, rated insulation voltage is 500 V, and impulse withstand voltage is 6 kV. Mechanical durability is 800,000 cycles, with a B10d of 4,000,000 over 20 years. IP65 protection applies, operating between -25°C and 70°C.
Cable Pull Switches Feature Summary
- Provides positive opening safety contacts for reliable emergency stopping in industrial machinery.
- Integrates a 24 V yellow pilot light for immediate local visual status indication.
- Constructed with a Zamak body and stainless steel cover to ensure robust environmental resistance.
- Designed for high mechanical endurance with a specified durability of 800,000 cycles.
Cable Pull Switches Applications
- Emergency stop systems for heavy industrial machinery
- Safety interlocking on conveyor belt systems
- Protection mechanisms for automated production lines
Cable Pull Switches Procurement Notes
Verify that the specific model number matches the required configuration, particularly the 24 V AC/DC pilot light supply and the inclusion of the booted reset push-button. Confirm that the trigger cable length does not exceed the maximum supported span of 30 meters. Ensure the installation environment falls within the specified temperature range of -25°C to 70°C and meets the IP65 ingress protection requirements. Check compliance with relevant regional directives such as EN/IEC 60947-5-5 and UL category NISD if applicable to the deployment location.
Cable Pull Switches Selection Notes
Select this model when a latching emergency stop function is required alongside local visual signaling. The integrated 24 V pilot light distinguishes it from non-indicating variants. Consider the 30-meter maximum trigger cable length and the need for screw clamp terminals accepting 0.5 to 1.5 mm² conductors. The device supports safety levels up to PL e and Category 4 when paired with appropriate monitoring systems. Verify that the physical dimensions and mounting orientation align with the machine guard design constraints.
Cable Pull Switches Part Context
This component belongs to the Telemecanique XY2CH series of latching emergency stop rope pull switches. It is designed to comply with EN/ISO 13850 and Machinery Directive 2006/42/EC standards. The series utilizes Zamak bodies and offers various contact configurations and lighting options. This specific unit provides dual functionality through its NC/NO contact block and dedicated 24 V indicator circuit, facilitating both machine shutdown and operator awareness in hazardous scenarios.
Cable Pull Switches Replacement Considerations
Direct substitutes within the same product line include models with identical electrical ratings but different lighting voltages or reset types. For example, the XY2CH13250H29 is a similar straight-mount switch but lacks the specific 24 V pilot light configuration found in the XY2CH13253. When replacing, ensure the new part maintains the same 1 NC + 1 NO contact arrangement and compatible terminal specifications.
Cable Pull Switches FAQ
What is the maximum trigger cable length supported by this switch?
The maximum trigger cable length is 30 meters (98.43 ft).
How is the device reset after an emergency stop activation?
The device is reset manually using the integrated booted push-button located on the housing.
What are the contact ratings for AC and DC circuits?
The rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13.