XY2CH13370 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CH13370
- Description:CABLE PULL SWITCH 2NC 3A 240V
- Series:XY2CH
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NC
- Switch Function:On-Off
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:30m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CH13370
Cable Pull Switches Overview
The Telemecanique Sensors XY2CH13370 is a latching emergency stop rope pull switch from the XY2CH series. It features a red Zamak body with a stainless steel cover and utilizes a mushroom head push-button for reset. The device incorporates two normally closed (NC) contacts with slow-break operation, rated at 3 A AC-15 and 0.27 A DC-13. It supports a maximum trigger cable length of 30 m and offers IP65 protection. The unit complies with EN/IEC 60947-5-1 and EN/ISO 13849-1 standards, achieving PL e, Category 4, and SIL 3 safety levels when used with appropriate monitoring systems.
Cable Pull Switches Feature Summary
- Latching emergency stop functionality with positive opening contacts compliant with EN/IEC 60947-5-1
- Mushroom head push-button reset mechanism without integrated pilot light
- High mechanical durability rated at 8 million operating cycles over a 20-year lifetime
- Robust housing constructed from Zamak alloy with a stainless steel cover
Cable Pull Switches Applications
- Emergency stop integration in industrial machinery requiring certified safety switches
- Safety circuit implementation in manufacturing equipment adhering to Machinery Directive 2006/42/EC
- Hazardous area monitoring where high ingress protection and corrosion resistance are required
Cable Pull Switches Procurement Notes
Verify that the specific application requires a latching configuration rather than a non-latching variant within the XY2CH family. Confirm that the system design includes an appropriate external monitoring relay or PLC logic capable of validating the safety level requirements, as the switch alone reaches PL e, Category 4, and SIL 3 only when correctly wired with compatible monitoring devices. Ensure the installation environment falls within the specified ambient air temperature range of -25°C to 70°C. Check that the wiring terminals accommodate the required conductor cross-sections of 0.5 to 1.5 mm² and that the tightening torque is maintained between 0.8 and 1.2 N.m for secure connections.
Cable Pull Switches Selection Notes
Select this model when a latching emergency stop response is mandatory to prevent automatic restart after a fault condition. The choice is driven by the need for high safety integrity levels (PL e, Cat 4, SIL 3) in critical applications. Consider the physical dimensions and the requirement for three Pg 13.5 cable entries during layout planning. Evaluate the environmental conditions against the IP65 rating and the material compatibility of the Zamak and stainless steel housing. This component is suitable for applications demanding strict compliance with EN/IEC 60947-5-5 standards for safety-related parts of control systems.
Cable Pull Switches Part Context
The XY2CH13370 belongs to the Telemecanique Emergency stop rope pull switches range, specifically the XY2CH series. These devices are designed for direct mounting and provide reliable safety shutdown capabilities. The series is characterized by its robust construction and compliance with international safety standards including EN/ISO 13850 and EN/IEC 60204-1. The product line serves various industrial sectors requiring certified emergency stopping mechanisms for work equipment under the Work Equipment Directive 2009/104/EC.
Cable Pull Switches Replacement Considerations
Direct substitution requires matching the latching function, 2 NC contact configuration, and identical mounting dimensions. Verify that any alternative device meets the same IP65 protection rating and operates within the -25°C to 70°C temperature range. Ensure the replacement supports the required safety levels (PL e, Cat 4, SIL 3) with compatible monitoring systems. Cross-reference terminal types and cable entry specifications to maintain electrical and mechanical compatibility.
Cable Pull Switches FAQ
What is the mechanical durability rating of the XY2CH13370?
The switch has a mechanical durability of 800,000 cycles.
How is the XY2CH13370 reset after activation?
It is reset using the integrated mushroom head push-button.
What safety levels can be achieved with this switch?
It can reach PL = e, Category 4, and SIL 3 when used with the appropriate monitoring system and correct wiring.