XY2CH13450 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 1NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CH13450
- Description:CABLE PULL SWITCH 1NC 3A 240V
- Series:XY2CH
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NO/NC
- Switch Function:On-Off, Off-On
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:30m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CH13450
Cable Pull Switches Overview
The XY2CH13450 is a latching emergency stop rope pull switch from the Telemecanique XY2CH series. It features a Zamak body with a stainless steel cover and red RAL 3000 housing. The unit includes one normally closed (NC) and one normally open (NO) contact with slow-break operation, reset via a key-release push-button (Key number 421). Rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13. Conventional enclosed thermal current is 10 A, with rated insulation voltage of 500 V and impulse withstand voltage of 6 kV. Maximum trigger cable length is 30 m, supported every 5 m. IP65 protection, operating temperature -25°C to 70°C, mechanical durability 800,000 cycles, B10d 4,000,000.
Cable Pull Switches Feature Summary
- Latching emergency stop functionality with positive opening contacts compliant with EN/IEC 60947-5-1.
- Reset mechanism utilizes a dedicated key-release push-button for controlled activation.
- Constructed with a Zamak body and stainless steel cover for robust environmental resistance.
- Capable of reaching Safety Integrity Level SIL 3 and Performance Level PL e when integrated with appropriate monitoring systems.
Cable Pull Switches Applications
- Emergency stop circuits in industrial machinery requiring latching safety functions.
- Safety interlocking systems on conveyor lines and material handling equipment.
- Applications necessitating compliance with EN/ISO 13849-1 Category 4 or SIL 3 standards.
- Hazardous area monitoring where remote cable pull actuation is required.
Cable Pull Switches Procurement Notes
Verify that the specific application environment aligns with the IP65 rating and operating temperature range of -25°C to 70°C. Confirm that the monitoring system utilized in the control circuit is capable of supporting the specified safety levels, including PL e and SIL 3, as these ratings depend on correct wiring and external system configuration. Ensure the installation allows for the maximum trigger cable length of 30 meters with support intervals not exceeding 5 meters to maintain mechanical integrity. Check that the screw clamp terminals accommodate the wire cross-section range of 0.5 to 1.5 mm² and adhere to the tightening torque specifications of 0.8 to 1.2 N.m. Review the UL category NISD certification requirements if the equipment is intended for use in regions mandating this specific standard.
Cable Pull Switches Selection Notes
Select the XY2CH13450 when a latching emergency stop function is required, distinguishing it from non-latching variants within the XY2CH family. The choice depends on the need for a key-release reset mechanism to prevent unauthorized restarts. Evaluate the electrical load against the rated operational currents of 3 A AC and 0.27 A DC to ensure compatibility with the control circuitry. Consider the physical dimensions and mounting orientation, noting the RH or LH side anchor point options. Assess the environmental conditions to confirm suitability for the IP65 rating and verify that the Red RAL 3000 housing color meets site visibility requirements. Compare the B10d value of 4,000,000 against the expected maintenance lifecycle to determine long-term reliability needs.
Cable Pull Switches Part Context
The XY2CH13450 belongs to the Telemecanique Preventa XY2CH range of emergency stop rope pull switches. This series is designed for safety applications in industrial automation, providing reliable detection of cable tension loss. The product adheres to Machinery Directive 2006/42/EC and standards such as EN/IEC 60204-1 and EN/ISO 13850. It is part of Schneider Electric's broader portfolio of safety sensors and switches, emphasizing compliance with international safety regulations including UL category NISD and CCC certifications. The component integrates into larger safety loops to monitor critical machine boundaries.
Cable Pull Switches Replacement Considerations
Direct replacement requires matching the latching function, 1 NC + 1 NO contact configuration, and key-reset mechanism. Verify compatibility with existing terminal blocks and cable entry sizes (Pg 13.5). Ensure the substitute part supports the same safety integrity levels (SIL 3, PL e) and electrical ratings (3 A AC, 0.27 A DC). Non-latching models or those with different contact compositions are not suitable substitutes without re-engineering the safety logic.
Cable Pull Switches FAQ
What is the maximum trigger cable length supported by this switch?
The maximum trigger cable length is 30 meters (98.43 ft), with cable supports required at intervals of 5 meters (16.40 ft).
How is the switch reset after an emergency stop event?
The switch is reset using a key-release push-button. The specific key number for operation is 421.
What safety performance levels can be achieved with this component?
With an appropriate monitoring system and correct wiring, the switch can reach Performance Level (PL) e according to EN/ISO 13849-1, Category 4, and Safety Integrity Level (SIL) 3 according to EN/IEC 61508.
Explore related parts through Switches, all product categories, ChipApex homepage.
ChipApex | Global Electronic Components Supplier