XY2CH13470 is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 3A 240V. Review the specifications below when checking this part for your BOM.
Cable Pull Switches specifications for XY2CH13470
- Description:CABLE PULL SWITCH 2NC 3A 240V
- Series:XY2CH
- Mfr:Telemecanique Sensors
- Package:Box
- Circuit:DPST-NC
- Switch Function:On-Off
- Current Rating (Amps):3A (AC), 270mA (DC)
- Voltage Rating - AC:240V
- Voltage Rating - DC:250V
- Maximum Cable Length:30m
- Features:Push Button Emergency Stop Switch
- pa_operating-force:
- pa_ingress-protection:
- pa_operating-temperature:
Cable Pull Switches datasheet and documents for XY2CH13470
Cable Pull Switches Overview
The Telemecanique Sensors XY2CH13470 is a latching emergency stop rope pull switch from the XY2CH series. It features a Zamak body with a stainless steel cover and red RAL 3000 housing. The device includes two normally closed (NC) contacts with slow-break operation, reset via a key-release push-button using key number 421. Electrical ratings include 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13. It supports a maximum trigger cable length of 30 m, has an IP65 rating, and operates within -25°C to 70°C. Mechanical durability is rated at 800,000 cycles.
Cable Pull Switches Feature Summary
- Provides positive opening action compliant with EN/IEC 60947-5-1 for reliable emergency stopping.
- Features a latching mechanism requiring manual reset via a dedicated key-release push-button.
- Constructed with a Zamak body and stainless steel cover for robust environmental protection.
- Designed to reach Safety Integrity Level SIL 3 and Performance Level e when used with appropriate monitoring.
Cable Pull Switches Applications
- Emergency stop systems on industrial machinery
- Safety interlocking in automated production lines
- Hazardous area equipment shutdown protocols
Cable Pull Switches Procurement Notes
Verify that the specific application requires a latching emergency stop function rather than a non-latching variant. Confirm that the control circuitry can accommodate the 2 NC contact configuration and the specified current ratings of 3 A AC or 0.27 A DC. Ensure the installation environment falls within the -25°C to 70°C operating temperature range and meets the IP65 protection requirements. Check if the required safety level (SIL 3 or PL e) aligns with the overall system design and monitoring capabilities. Validate that the 30 m maximum cable length is sufficient for the intended layout.
Cable Pull Switches Selection Notes
Select this model when a latching emergency stop is mandated by safety standards. The XY2CH series is suitable for applications requiring high mechanical durability and positive opening contacts. Consider the physical dimensions and mounting orientation relative to the available space. Evaluate the need for the specific key-release reset mechanism to prevent unauthorized restarts. Compare against non-latching alternatives if immediate automatic reset after cable tension release is preferred.
Cable Pull Switches Part Context
The XY2CH13470 belongs to the Telemecanique Emergency stop rope pull switches family, specifically the XY2CH line. This series is designed for critical safety applications where immediate and secure machine shutdown is necessary. The product adheres to international standards including EN/IEC 60947-5-1 and EN/ISO 13850. It is part of Schneider Electric's broader portfolio of industrial automation and safety components.
Cable Pull Switches Replacement Considerations
Direct replacement models within the same series include other variants of the XY2CH latching rope pull switches. Verify compatibility with existing mounting hardware and cable entry points (Pg 13.5). Ensure that any substitute maintains the same contact configuration (2 NC) and reset method (key-release) to preserve safety integrity.
Cable Pull Switches FAQ
How is the switch reset after activation?
The switch is reset manually using a key-release push-button. Key number 421 is required for this operation.
What is the maximum trigger cable length supported?
The maximum trigger cable length is 30 meters (98.43 ft).
Does the switch provide local signaling?
No, this specific model does not include a pilot light for local signaling.
Explore related parts through Switches, all product categories, ChipApex homepage.