Cable Pull Switches XY2CH14250TK product image

XY2CH14250TK

$694.87
  • Description:CABLE PULL SWITCH 2NC 3A 240V
  • Series:XY2CH
  • Mfr:Telemecanique Sensors
  • Package:Box

SKU:XY2CH14250TK Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

XY2CH14250TK is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 3A 240V. Review the specifications below when checking this part for your BOM.

Cable Pull Switches specifications for XY2CH14250TK

  • Description:CABLE PULL SWITCH 2NC 3A 240V
  • Series:XY2CH
  • Mfr:Telemecanique Sensors
  • Package:Box
  • Circuit:3PST-2NC/1NO
  • Switch Function:On-Off, Off-On
  • Current Rating (Amps):3A (AC), 270mA (DC)
  • Voltage Rating - AC:240V
  • Voltage Rating - DC:250V
  • Maximum Cable Length:30m
  • Features:Push Button Emergency Stop Switch
  • pa_operating-force:
  • pa_ingress-protection:
  • pa_operating-temperature:

Cable Pull Switches datasheet and documents for XY2CH14250TK

XY2CH14250TK

Cable Pull Switches Overview

The Telemecanique Sensors XY2CH14250TK is a latching emergency stop rope pull switch from the XY2C series. It features a Zamak body with a stainless steel cover and red RAL 3000 housing. The device includes 2 NC + 1 NO contacts with slow-break operation, rated for 3 A at 240 V AC or 0.27 A at 250 V DC. It supports a trigger cable length up to 30 m (98.43 ft) and offers IP66 protection. Safety performance reaches PL e per EN/ISO 13849-1, Category 4, and SIL 3 per EN/IEC 61508. Mechanical durability is 800,000 cycles with a B10d of 4,000,000 over 20 years.

Cable Pull Switches Feature Summary

  • Latching emergency stop functionality with reset by booted push-button
  • Positive opening contact operation compliant with EN/IEC 60947-5-1
  • High safety integrity reaching PL e, Category 4, and SIL 3
  • Robust construction with Zamak body and stainless steel cover

Cable Pull Switches Applications

  • Emergency stop systems in industrial machinery
  • Safety interlocking for conveyor belts and material handling equipment
  • Applications requiring high environmental protection (IP66)
  • Machinery subject to Machinery Directive 2006/42/EC compliance

Cable Pull Switches Procurement Notes

Verify that the selected monitoring system configuration aligns with the required safety level (PL e, Category 4, or SIL 3), as these ratings depend on correct wiring and external circuit design. Confirm that the trigger cable length does not exceed the maximum supported distance of 30 meters to ensure reliable operation. Ensure that short-circuit protection utilizes a 10 A cartridge fuse (gG type) as specified. Check compatibility with local standards such as CSA C22.2 No 14 if operating in Canada. Review the EU RoHS declaration and REACh status for regulatory compliance requirements specific to your region.

Cable Pull Switches Selection Notes

Choose this model when a latching emergency stop function is mandatory, distinguishing it from non-latching variants. Select based on the need for positive opening contacts to guarantee safe disconnection upon activation. Consider the IP66 rating for environments exposed to dust and water jets. Verify that the 2 NC + 1 NO contact configuration meets the logical requirements of the safety circuit. Assess the mechanical durability of 800,000 cycles against expected operational frequency. Ensure the mounting orientation supports the RH or LH side anchor point options available.

Cable Pull Switches Part Context

The XY2CH14250TK belongs to the Telemecanique Emergency stop rope pull switches XY2C range. This series is designed for robust industrial applications requiring reliable emergency stopping capabilities. The device integrates into broader safety architectures defined by EN/ISO 13850 and EN/IEC 60947-5-5 standards. It is part of a modular ecosystem where compatible trigger cables and accessories can be sourced separately. The product carries CE marking and complies with the Work Equipment Directive 2009/104/EC.

Cable Pull Switches Replacement Considerations

Public confirmed substitute part numbers are not provided in the source documentation. Users should consult official Schneider Electric or Telemecanique Sensors catalogs for cross-reference data regarding equivalent models within the XY2CE family or alternative safety switch series. Verify dimensional and electrical compatibility before substitution.

Cable Pull Switches FAQ

What is the maximum trigger cable length supported by this switch?

The maximum trigger cable length is 30 meters (98.43 feet).

How is the switch reset after an emergency stop event?

The switch is reset using a booted push-button.

What safety levels can this device achieve?

It can reach Performance Level e (PL e) per EN/ISO 13849-1, Category 4, and Safety Integrity Level 3 (SIL 3) per EN/IEC 61508, depending on the monitoring system and wiring.