Cable Pull Switches XY2CH14290TK product image

XY2CH14290TK

$451.72
  • Description:CABLE PULL SWITCH 2NC 1.5A 240V
  • Series:XY2C
  • Mfr:Telemecanique Sensors
  • Package:Box

SKU:XY2CH14290TK Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:[email protected]
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

XY2CH14290TK is listed in the Cable Pull Switches range at ChipApex. The manufacturer field lists Telemecanique Sensors. Its product description is CABLE PULL SWITCH 2NC 1.5A 240V. Review the specifications below when checking this part for your BOM.

Cable Pull Switches specifications for XY2CH14290TK

  • Description:CABLE PULL SWITCH 2NC 1.5A 240V
  • Series:XY2C
  • Mfr:Telemecanique Sensors
  • Package:Box
  • Circuit:3PST-2NC/1NO
  • Switch Function:On-Off, Off-On
  • Current Rating (Amps):1.5A (AC), 100mA (DC)
  • Voltage Rating - AC:240V
  • Voltage Rating - DC:250V
  • Maximum Cable Length:30m
  • Features:-
  • pa_operating-force:
  • pa_ingress-protection:
  • pa_operating-temperature:

Cable Pull Switches datasheet and documents for XY2CH14290TK

XY2CH14290TK

Cable Pull Switches Overview

The Telemecanique Sensors XY2CH14290TK is a latching emergency stop rope pull switch from the XY2CH series. It features a Zamak body with a stainless steel cover and blue housing. The device provides 2 NC + 1 NO contacts with slow-break operation. Rated operational current is 1.5 A at 240 V AC-15 and 0.1 A at 250 V DC-13, with a conventional enclosed thermal current of 6 A. Rated insulation voltage is 400 V. It supports a maximum trigger cable length of 30 m (98.43 ft) and includes three Pg 13.5 tapped entries for cable connections. Mechanical durability is rated at 800,000 cycles, with a B10d value of 4,000,000 over a 20-year lifetime.

Cable Pull Switches Feature Summary

  • Latching emergency stop functionality activated by trigger cable tension loss
  • Reset mechanism utilizes a booted push-button to restore normal operation
  • Positive opening contact design compliant with EN/IEC 60947-5-1 standards
  • High safety integrity capable of reaching PL e, Category 4, or SIL 3 with appropriate monitoring

Cable Pull Switches Applications

  • Emergency stop systems for industrial machinery requiring rope pull activation
  • Conveyor belt systems where remote emergency stopping is necessary
  • Automated production lines integrated with safety monitoring circuits
  • Equipment subject to EN/IEC 60204-1 electrical safety requirements

Cable Pull Switches Procurement Notes

Verify that the selected model matches the specific contact configuration and cable entry requirements for the installation environment. Confirm that the monitoring system utilized in the application is compatible with the device's safety performance levels, including PL e, Category 4, or SIL 3 capabilities as defined by EN/ISO 13849-1 and EN/IEC 61508. Ensure that the wiring terminals support the specified conductor sizes, ranging from 0.34 mm² to 1 mm² using screw clamp connections. Check compliance with local machinery directives and verify that the environmental conditions, such as corrosive atmospheres and temperature ranges from -40°C to 70°C, are within the device's operational limits. Review UL category NISD certification if applicable to the region of use.

Cable Pull Switches Selection Notes

Select this component when a latching emergency stop function is required with high mechanical durability and robust environmental protection. The XY2CH14290TK is suitable for applications demanding positive opening contacts and slow-break operation to ensure reliable circuit interruption. Consider the maximum trigger cable length of 30 meters when planning the layout of the safety loop. The device's IP65 rating makes it appropriate for environments where dust ingress and water jets may occur. Evaluate the need for the specific 2 NC + 1 NO contact arrangement against the control logic requirements of the safety relay or PLC being used.

Cable Pull Switches Part Context

The XY2CH14290TK belongs to the Telemecanique Emergency stop rope pull switches XY2C and XY2CH family. This series is designed for critical safety applications where immediate machine shutdown is essential. The product adheres to international standards including EN/IEC 60947-5-5 and EN/ISO 13850. It is part of Schneider Electric's broader portfolio of safety components, offering compatibility with various industrial automation systems. The device is manufactured with attention to sustainability, being toxic heavy metal free and mercury free, while complying with EU RoHS directives.

Cable Pull Switches Replacement Considerations

Direct replacement requires verifying identical contact configuration (2 NC + 1 NO), mounting dimensions, and cable entry types (Pg 13.5). Ensure the substitute device supports the same rated operational currents and insulation voltages. Compatibility with existing safety monitoring systems must be confirmed, particularly regarding safety integrity levels and B10d values. Physical fitment within the enclosure and alignment with the trigger cable path should be assessed before installation.

Cable Pull Switches FAQ

What is the reset method for the XY2CH14290TK?

The device is reset using a booted push-button located on the housing.

What is the maximum trigger cable length supported?

The maximum trigger cable length is 30 meters (98.43 feet).

Does the switch feature positive opening contacts?

Yes, the contacts operate with positive opening as per EN/IEC 60947-5-1.

XY2CH14290TKXY2CH14290TK
$451.72
Buy Now