AD585SQ is listed in the Instrumentation, Op Amps, Buffer Amps range at ChipApex. The manufacturer field lists Analog Devices Inc. Its product description is IC SAMPL/HOLD 1 CIRCUIT 14CERDIP. Review the specifications below when checking this part for your BOM.
Instrumentation, Op Amps, Buffer Amps specifications for AD585SQ
- Description:IC SAMPL/HOLD 1 CIRCUIT 14CERDIP
- Series:-
- Mfr:Analog Devices Inc.
- Package:Tube
- Amplifier Type:Sample and Hold
- Number of Circuits:1
- Output Type:-
- Slew Rate:10V/µs
- Gain Bandwidth Product:-
- Current - Input Bias:2 nA
- Voltage - Input Offset:2 mV
- Current - Supply:10mA
- Current - Output / Channel:50 mA
- Voltage - Supply Span (Min):10 V
- Voltage - Supply Span (Max):36 V
- Operating Temperature:-55°C ~ 125°C
- Grade:-
- Qualification:-
- Mounting Type:Through Hole
- Package / Case:14-CDIP (0.300", 7.62mm)
- Supplier Device Package:14-CERDIP
- -3db Bandwidth:2 MHz
Instrumentation, Op Amps, Buffer Amps datasheet and documents for AD585SQ
Instrumentation, Op Amps, Buffer Amps Overview
The AD585SQ is a monolithic sample-and-hold amplifier manufactured by Analog Devices Inc., housed in a 14-pin ceramic dual in-line package (Cerdip). It operates within an extended temperature range of –55°C to +125°C. The device features a maximum acquisition time of 3 μs for a 10 V step, a low droop rate of 1.0 mV/ms, and an aperture jitter of 0.5 ns. It supports ±12 V or ±15 V power supplies with a supply current of 10 mA. Key electrical parameters include a slew rate of 10 V/μs, a small-signal bandwidth of 2 MHz, and an input bias current of 2 nA.
Instrumentation, Op Amps, Buffer Amps Feature Summary
- Monolithic integration of a high-performance operational amplifier, ultralow leakage analog switch, and FET input integrating amplifier.
- Internal pretrimmed application resistors enable versatile gain configurations including +1, -1, and +2.
- Built-in internal hold capacitor eliminates the need for external components for standard operation.
- Differential logic inputs allow compatibility with various logic families through programmable threshold referencing.
Instrumentation, Op Amps, Buffer Amps Applications
- High-speed data acquisition systems requiring fast acquisition and low droop
- Data distribution systems
- Analog delay and storage circuits
- Peak amplitude measurements
Instrumentation, Op Amps, Buffer Amps Procurement Notes
Verify component authenticity through authorized distributors or direct manufacturer channels. Confirm the specific SQ grade designation corresponds to the required military temperature range specifications. Ensure proper handling procedures are followed due to the ceramic package type. Cross-reference datasheet revisions to ensure compatibility with existing system designs.
Instrumentation, Op Amps, Buffer Amps Selection Notes
Select this component when extended temperature performance is critical for the application environment. Consider the internal hold capacitance limitations if lower droop rates are required over long hold periods. Evaluate the interface requirements against the differential logic input capabilities. Assess the trade-off between acquisition speed and offset voltage based on the specific signal characteristics.
Instrumentation, Op Amps, Buffer Amps Part Context
The AD585 series represents a family of precision sample-and-hold amplifiers designed for high-speed applications. The SQ variant specifically targets environments requiring robust performance across wide thermal variations. It serves as a bridge between analog signals and digital conversion processes, ensuring signal integrity during the sampling phase.
Instrumentation, Op Amps, Buffer Amps Replacement Considerations
Public confirmed substitute part numbers: None available in source material.
Instrumentation, Op Amps, Buffer Amps FAQ
How does the AD585 handle logic level interfacing?
The device uses a differential amplifier input stage for HOLD and /HOLD signals, allowing the logic threshold to be programmed by referencing one input to a suitable voltage, enabling compatibility with TTL, CMOS, and ECL logic families.
What is the impact of adding an external hold capacitor?
Adding an external capacitor reduces the droop rate but increases the acquisition time. The sample-to-hold offset also decreases proportionally to the total capacitance value.
Explore related parts through Amplifiers, Linear, Integrated Circuits (ICs), all product categories.
ChipApex | Global Electronic Components Supplier