Brand

Product categories

Filter by price :
Relays

Electrical Relays for Control and Power Switching

Relays and contactors are devices used to switch or interrupt the flow of electrical current in one or more circuits, using a control signal which is galvanically isolated from the circuit(s) being controlled, with various sub-groups demarcated along lines of device construction or intended application. Traditionally and still-commonly based on the use of an electromagnet to open or close a set of mechanical switch contacts, newer devices using solid-state technologies are also widely available, with both types having characteristics to recommend them under different application conditions.

Screen Default Ranking Price By Date
Select productsMfrDescriptionPackageSupplier Device PackageMounting TypeSeriesOperating Temperature
c3controlsSCKT 15A, MINI BLADE GRDD TERMBagDIN RailGR
c3controlsMINI, 8 BLADE GUARDED, 15ABagDIN RailGR
c3controlsMINI,8 BLADE UNGUARDED,15ABagDIN RailGR
c3controls11 BLADE GUARDED, 20/25 ABagDIN RailGR
c3controls11 BLADE UNGUARDED, 20/25 ABagDIN RailGR
c3controls14 BLADE UNGUARDED, 7 ABagDIN RailGR
c3controls14 BLADE UNGUARDED, 15 ABagDIN RailGR
c3controls8 PIN GUARDED, 10 ABagDIN RailGR

Electrical Relay: Features and Specifications

  • Function in the design. A relay lets one control signal switch a separate load path through contacts or a semiconductor output. Start with the role the component plays in the switching assembly. Choose the switching technology and check the load type, inrush and control requirements. A related catalog entry helps explain the distinction. An RF relay is characterized for switching high-frequency signal paths. Compare the role of each in the assembly before choosing between the two categories; a similar name does not necessarily describe the same job.
  • J104D2C12VDC.20S at a glance. The listing for J104D2C12VDC.20S gives mounting type as Through Hole, coil voltage as 12VDC, contact form as DPDT (2 Form C). Read these entries together with the manufacturer’s description. They belong to this ordering code; another device in the same family can have a different implementation. Open the product record before copying a value into a bill of materials, and retain the units and any qualifiers alongside the number so that a later comparison uses the same definition.
  • Differences within the range. For coil current, J104D2C12VDC.20S is listed as 16.7 mA and J104D2C12VDC.36S as 30 mA. When comparing relays, distinguish a property shown for an individual model from a requirement shared by the whole design. Two rows can appear similar when only their short descriptions are visible. Look at the full entry, then use the manufacturer’s drawing or characteristic table to resolve any difference that would affect assembly, operation or the acceptance test.

Electronic Relay: Applications and Design Considerations

  • Typical operating conditions. Relays switch power, route signals and isolate control electronics from a load. For this use, specify control signal, load waveform, switching frequency and the required state when control power is removed. Write down the condition that matters to the finished equipment before narrowing the list of parts. A prototype that works at a single bench setting can still miss the requirement when installed. Include at least one representative operating case and the most demanding credible case in the comparison.
  • Integration example. The listing for J104D2C12VDC.36S gives coil voltage as 12VDC, contact form as DPDT (2 Form C), contact rating (current) as 2:00 AM. In an application review, mark which of these properties the surrounding design fixes and which can still change. A second catalog example gives another point of comparison. The listing for AZ9731-1C-12DC4 gives contact rating (current) as 30 A, switching voltage as 75VDC - Max, must operate voltage as 7.8 VDC. When the design has to fit an established interface, use the documentation for that interface alongside the product record, and resolve discrepancies before committing the layout or ordering evaluation quantities.
  • Checks on the prototype. Check the load type used for the published rating. A resistive load, an inductive load and a capacitive input impose different stresses during switching. Record the setup, the operating conditions and the observed result so another engineer can repeat the check. For relays, pay particular attention to the requirement behind this selection guidance: choose the switching technology and check the load type, inrush and control requirements. If the result is marginal, change one condition at a time and compare it with the original measurement before attributing the difference to the component.

Selection Criteria for Electromechanical Relay

  • Define the acceptance criteria. Choose the switching technology and check the load type, inrush and control requirements. Put the nonnegotiable requirements in a short comparison table before looking at price. For this category, useful starting columns from the catalog include mounting type, coil voltage, contact form, contact rating (current). Give each critical value a unit and an acceptable range. Where a catalog entry leaves a field blank, flag it for confirmation in the datasheet rather than assigning a value from another member of the family.
  • Compare exact ordering codes. The listing for AZ9731-1C-12DC4 gives coil voltage as 12VDC, contact form as SPDT (1 Form C), contact rating (current) as 30 A. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For operating temperature, the respective entries for J104D2C12VDC.36S and AZ9731-1C-12DC4 are -40°C ~ 85°C and -40°C ~ 125°C. Check which of these values the assembly drawing or design specification requires. A typical value measured under one set of conditions is a poor acceptance limit unless the manufacturer also specifies the relevant guarantee under your operating conditions.
  • Prepare the purchase specification. For a quotation, identify the required relays by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Include quantity, delivery requirements and any packaging constraint imposed by the assembly process. Before approving an alternative for the switching assembly, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
Add ComparisonUp to 4 can be added

    Recommended Products

    Recent News