DPX1608LKEER2460LView Product
RF Multiplexers
RF Multiplexers use bi-directional bandpass filters to combine RF signals for transmission through a single coaxial cable or to split a combined signal into separate signals for transmission through independent coax cables. Types of multiplexing include diplexing, duplexing. triplexing, quadplexing and quintplexing. Multiplexors are differentiated by their frequency bands, low band attenuation, high band attenuation, return loss and mounting type.
RF Multiplexers: Features and Specifications
- Function in the design. An RF multiplexer combines or separates bands through frequency-selective paths. Start with the role the component plays in the RF signal path. Match each passband, isolation between ports and power rating. RFID reader ICs generate or process signals used to interrogate compatible transponders. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- 0500DP44A1215001E at a glance. The listing for 0500DP44A1215001E gives type as Diplexer, frequency bands (low / high) as 950MHz ~ 1.45GHz / 1.65GHz ~ 2.15GHz, low band attenuation (min / max db) as 30.00dB / -. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For frequency bands (low / high), 0500DP44A1215001E is listed as 950MHz ~ 1.45GHz / 1.65GHz ~ 2.15GHz and 0859DP18A1920001E as 824MHz ~ 894MHz / 1.85GHz ~ 1.99GHz. When comparing rf multiplexers, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
RF Multiplexers: Applications and Design Considerations
- Typical operating conditions. It allows different bands to share an antenna feed or transmission line. For this use, specify operating band, port impedance, signal level and loss in cables or board traces. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for 0859DP18A1920001E gives frequency bands (low / high) as 824MHz ~ 894MHz / 1.85GHz ~ 1.99GHz, low band attenuation (min / max db) as 20.00dB / 0.75dB, high band attenuation (min / max db) as 20.00dB / 0.55dB. In an application review, mark which of these properties the surrounding design fixes and which can still change. The listing for 0790DP15A2205001E gives return loss (low band / high band) as 9.5dB / 9.5dB, type as Diplexer, frequency bands (low / high) as 617MHz ~ 960MHz / 1.71GHz ~ 2.7GHz. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Define the measurement reference plane. A result that includes cable and connector loss cannot be compared directly with a specification at the device ports. Record the setup, the operating conditions and the observed result so another engineer can repeat the check. During the rf multiplexers check, match each passband, isolation between ports and power rating. If the result is marginal, change one condition at a time and compare it with the original measurement before attributing the difference to the component.
Selection Criteria for RF Multiplexers
- Define the acceptance criteria. Match each passband, isolation between ports and power rating. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include type, frequency bands (low / high), low band attenuation (min / max db), high band attenuation (min / max db). Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for 0790DP15A2205001E gives low band attenuation (min / max db) as 30.00dB / -, high band attenuation (min / max db) as 25.00dB / -, return loss (low band / high band) as 9.5dB / 9.5dB. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For return loss (low band / high band), the respective entries for 0859DP18A1920001E and 0790DP15A2205001E are 12.0dB / 12.0dB and 9.5dB / 9.5dB. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required rf multiplexers by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the RF signal path, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
ChipApex | Global Electronic Components Supplier