CL2LAAT020D-C-T1View Product
Passive Delay Lines
A delay line is a discrete surface or through-hole mount device that allows a signal to be delayed by a fixed time interval. Delay lines are widely used building blocks in methods to simulate room acoustics, musical instruments, audio effects, and are used to help solve TTL, and ECL timing and clock skew issues. They are differentiated by fixed delay times from 40 ps to 22.6 ns.
Passive Delay Lines: Features and Specifications
- Function in the design. A passive delay line introduces a specified propagation delay without an active clock input. Start with the role the component plays in the magnetic component. Match delay, impedance and the bandwidth of the waveform. Coupled windings transfer energy or signals through a shared magnetic field. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- XDL15-2-020S at a glance. The listing for XDL15-2-020S gives delay time as 2.12 ns, tolerance as ±0.28nS, operating temperature as -55°C ~ 85°C. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For delay time, XDL15-2-020S is listed as 2.12 ns and XDL15-3-030S as 2.85 ns. When comparing delay lines, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
Passive Delay Lines: Applications and Design Considerations
- Typical operating conditions. It can align signal paths or shape timing in compatible analog and pulse circuits. For this use, specify operating frequency, current waveform and the allowable loss or temperature rise. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for XDL15-3-030S gives tolerance as ±0.30nS, operating temperature as -55°C ~ 140°C, mounting type as Surface Mount. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for XDL20-3-050S gives package / case as Nonstandard, 2 Lead, delay time as 3.975 ns, tolerance as ±0.16nS. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Evaluate the component in its actual circuit. A small signal measurement at one frequency may tell little about heating or behavior under load. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the delay lines check, match delay, impedance and the bandwidth of the waveform. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for Passive Delay Lines
- Define the acceptance criteria. Match delay, impedance and the bandwidth of the waveform. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include delay time, tolerance, operating temperature, mounting type. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for XDL20-3-050S gives operating temperature as -55°C ~ 85°C, mounting type as Surface Mount, package / case as Nonstandard, 2 Lead. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For package / case, the respective entries for XDL15-3-030S and XDL20-3-050S are Nonstandard, 4 Lead and Nonstandard, 2 Lead. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required delay lines by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the magnetic component, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
ChipApex | Global Electronic Components Supplier









-768x745.jpg)