TFDU4301-TR1View Product
IrDA Transceiver Modules
Infrared transceivers incorporate an infrared emitter, a photodiode and control circuitry in a single device package for use in data transmission at rates as high as 16 megabits per second. Modules are available as Serial (SIR), Mid (MIR) and Far (FIR) variations with side or top view options. The Infrared Data Association (IrDa) provides protocol specifications for wireless data communication such as IrDA 1.x and IrPHY 1.x for use with infrared transceivers.
Irda Transceiver: Features and Specifications
- Function in the design. An IrDA transceiver combines an infrared emitter and receiver for a defined data link. Start with the role the component plays in the measurement assembly. Match the IrDA data rate, optical geometry and supply range. A proximity sensor detects a target without requiring physical contact. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- TFBS4711-TT1 at a glance. The listing for TFBS4711-TT1 gives data rate as 115.2kbs (SIR), voltage - supply as 2.7 V ~ 5.5 V, idle current, typ @ 25°c as 75 µA. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For voltage - supply, TFBS4711-TT1 is listed as 2.7 V ~ 5.5 V and TFBS4650-TR1 as 2.4 V ~ 3.6 V. When comparing irda transceiver modules, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
Irda Transceiver: Applications and Design Considerations
- Typical operating conditions. It supports short-range optical transfer between compatible endpoints. For this use, specify the physical quantity of interest, expected range, response time and influence of the mounting arrangement. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for TFBS4650-TR1 gives voltage - supply as 2.4 V ~ 3.6 V, idle current, typ @ 25°c as 75 µA, link range, low power as 50cm. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for TFBS4711-TR1 gives orientation as Side View, operating temperature as -30°C ~ 85°C, size as 6.0mm x 3.0mm x 1.9mm. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Test the complete measurement path, including mounting and signal conditioning. A repeatable reading at one point does not establish accuracy across the full range. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the irda transceiver modules check, match the IrDA data rate, optical geometry and supply range. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for Irda Transceiver
- Define the acceptance criteria. Match the IrDA data rate, optical geometry and supply range. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include data rate, voltage - supply, idle current, typ @ 25°c, link range, low power. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for TFBS4711-TR1 gives idle current, typ @ 25°c as 75 µA, link range, low power as 1m, orientation as Side View. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For standards, the respective entries for TFBS4650-TR1 and TFBS4711-TR1 are IrPHY 1.4 and IrPHY 1.2. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required irda transceiver modules by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the measurement assembly, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
ChipApex | Global Electronic Components Supplier













-768x745.jpg)