Products in this family are used primarily to provide informatic connectivity between endpoints that employ differing communication protocols and/or signaling methods. Examples include devices that connect an I2C bus to a UART, USB to I2C, SPI, Ethernet, or UART, Ethernet MACs and PHYs, and others. Also included are devices used to establish multi-way connections using interfaces designed for point-to-point communications, such as USB hub controllers.

Screen Default Ranking Price By Date
Select productsMfrDescriptionPackageSupplier Device PackageMounting TypeSeriesOperating Temperature
NXP USA Inc.IC CAN FAULT TOL INTRFACE 14SOICTube14-SO--40°C ~ 125°C
NXP USA Inc.IC TOLERANT CAN INT FAULT 14SOICTape & Reel (TR)14-SO--40°C ~ 125°C
NXP USA Inc.IC USB MINI UNIV CHARGING 20QFNTape & Reel (TR),Bulk20-QFN-EP (3x3)--40°C ~ 85°C
NXP USA Inc.IC CTRL PARALLEL/I2C BUS 20HVQFNTape & Reel (TR),Cut Tape (CT)20-HVQFN (5x5)--40°C ~ 85°C
NXP USA Inc.IC CONTROLLER PARALLEL INTERFACEBulk20-SO--40°C ~ 85°C
NXP USA Inc.IC CTRL PARALLEL/I2C BUS 20-DIPTube20-DIP--40°C ~ 85°C
NXP USA Inc.IC CTRL PARALLEL/I2C BUS 20TSSOPTube,Tube20-TSSOP--40°C ~ 85°C
NXP USA Inc.IC CTRL PARALLEL/I2C BUS 20TSSOPTape & Reel (TR),Cut Tape (CT)20-TSSOP--40°C ~ 85°C

Interface Controllers: Features and Specifications

  • Function in the design. Interface controllers manage transactions on a particular bus or physical connection. Start with the role the component plays in the board design. Match the host and downstream protocols, data rate and driver support. A special-purpose analog switch is designed for a particular signal path or protocol. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
  • 78Q8430-100IGT/F at a glance. The listing for 78Q8430-100IGT/F gives protocol as Ethernet, function as Controller, interface as Parallel. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
  • Differences within the range. The listing for 78Q8430-100IGTR/F gives interface as Parallel, standards as 10/100 Base-T/TX PHY, voltage - supply as 3.3V. When comparing controllers, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.

Interface Controllers: Applications and Design Considerations

  • Typical operating conditions. They link a host processor to peripherals and communication ports. For this use, specify supply sequencing, signal interfaces, timing requirements and the state of the circuit during startup. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
  • Integration example. The listing for 78Q8430-100IGTR/F gives function as Controller, interface as Parallel, standards as 10/100 Base-T/TX PHY. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for ADIN2111BCPZ gives voltage - supply as 1.71V ~ 3.46V, 3.13V ~ 3.46V, current - supply as 65mA, operating temperature as -40°C ~ 85°C (TA). For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
  • Checks on the prototype. Follow the signal through the surrounding circuitry. A compatible package and supply voltage do not establish that two devices have the same pin functions. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the controllers check, match the host and downstream protocols, data rate and driver support. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.

Selection Criteria for Interface Controllers

  • Define the acceptance criteria. Match the host and downstream protocols, data rate and driver support. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include protocol, function, interface, standards. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
  • Compare exact ordering codes. The listing for ADIN2111BCPZ gives interface as Serial, SPI, standards as IEEE 802.3, 10 Base-T PHY, voltage - supply as 1.71V ~ 3.46V, 3.13V ~ 3.46V. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For supplier device package, the respective entries for 78Q8430-100IGTR/F and ADIN2111BCPZ are 100-LQFP (14x14) and 48-LFCSP (7x7). Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
  • Prepare the purchase specification. For a quotation, identify the required controllers by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the board design, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.