REC8-4805DRWZ/H2/A/MView Product
DC-DC Converters
A device designed to change a direct current voltage input level to a one or more different direct current voltage output level.
DC DC Converters: Features and Specifications
- Function in the design. A DC-DC converter module changes one DC rail to another and may provide galvanic isolation. Start with the role the component plays in the power rail. Match input range, output load, isolation and derating at the actual ambient temperature. A board-mount LED driver regulates output for a compatible LED string or lighting load. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- AM1/2S-0303SH30Z at a glance. The listing for AM1/2S-0303SH30Z gives type as Isolated Module, number of outputs as 1, voltage - input (min) as 2.97V. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For voltage - isolation, AM1/2S-0303SH30Z is listed as 3 kV and AM1/2S-0303SZ as 1 kV. When comparing dc dc converters, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
DC To DC Converter: Applications and Design Considerations
- Typical operating conditions. It supplies local rails in distributed power systems and embedded equipment. For this use, specify input extremes, load steps, startup current and the heat that can leave the board. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for AM1/2S-0303SZ gives number of outputs as 1, voltage - input (min) as 2.97V, voltage - input (max) as 3.63V. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for AM1/2S-0305SH30Z gives voltage - output 1 as 5V, current - output (max) as 100mA, power (watts) as 0.5 mW. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Measure at the load as well as the module pins. Cabling, copper resistance and output capacitance influence the transient voltage the load actually sees. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the dc dc converters check, match input range, output load, isolation and derating at the actual ambient temperature. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for DC DC Converter Module
- Define the acceptance criteria. Match input range, output load, isolation and derating at the actual ambient temperature. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include type, number of outputs, voltage - input (min), voltage - input (max). Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for AM1/2S-0305SH30Z gives voltage - input (min) as 2.97V, voltage - input (max) as 3.63V, voltage - output 1 as 5V. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For efficiency, the respective entries for AM1/2S-0303SZ and AM1/2S-0305SH30Z are 76% and 70%. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required dc dc converters by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the power rail, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
ChipApex | Global Electronic Components Supplier