HM2R05PA5101N9View Product
Hard Metric Connectors
Hard Metric, Standard Backplane Connectors conform to a set of specifications for interconnection devices. These devices are used in board or panel systems where other circuit boards can be plugged into. These connectors usually have a 2.0 mm pitch from row to row and column to column. The number of positions range from 3 (Power) to 308 (220 + 88 Ground) in Pitch dimensions 0.050” (1.27 mm), 0.071” (1.80 mm), 0.079” (2.00 mm), 0.150” (3.81 mm), or 0.295” (7.50 mm).
Hard Metric Connectors: Features and Specifications
- Function in the design. Hard metric connectors use a defined metric grid and mating geometry. Start with the role the component plays in the mating assembly. Check the keying, contact pattern and mating height together. Specialized backplane families can combine signal contacts, power contacts or guide features. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- 43136 at a glance. The listing for 43136 gives connector type as Header, Male Pins, connector style as A 22, number of positions as 110. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For connector style, 43136 is listed as A 22 and 43138 as C 11. When comparing hard metric, standard, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
Hard Metric Connectors: Applications and Design Considerations
- Typical operating conditions. They connect daughtercards to modular backplanes. For this use, specify contact arrangement, mating direction, keying and clearance for installation or extraction. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for 43138 gives connector style as C 11, number of positions as 55, number of positions loaded as All. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for 43190 gives pitch as 0.079" (2.00mm), number of rows as 5, mounting type as Through Hole. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Review drawings of both halves at the same scale. Pin one, the mating face and the board view can appear reversed between drawings. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the hard metric, standard check, check the keying, contact pattern and mating height together. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for Hard Metric Connectors
- Define the acceptance criteria. Check the keying, contact pattern and mating height together. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include connector type, connector style, number of positions, number of positions loaded. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for 43190 gives number of positions as 110, number of positions loaded as All, pitch as 0.079" (2.00mm). Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For number of positions, the respective entries for 43138 and 43190 are 55 and 110. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required hard metric, standard by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the mating assembly, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.