56.OW70.1122SView Product
Safety Relays
Products in the safety relay category include a variety of device types designed to enhance or accommodate human safety interests in some way. They include standard relay types with force-guided contacts, industrial automation safety relay products that provide for verification of contact state, and relays designed to accommodate electrical interfacing between hazardous (e.g. potentially flammable or explosive atmosphere) and non-hazardous areas within a working environment.
Safety Relays: Features and Specifications
- Function in the design. Safety relays have model-specific features for use in monitored safety functions. Start with the role the component plays in the switching assembly. Check the exact device certification, contact arrangement and monitoring requirements against the system design. A signal relay switches low-level circuits where contact behavior at small currents matters. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- 1000842 at a glance. The listing for 1000842 gives mounting type as DIN Rail, coil voltage as 230VAC, contact form as SPST-NO (1 Form A) x 2. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For coil voltage, 1000842 is listed as 230VAC and 1003100 as 24VAC/DC. When comparing safety relays, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
Safety Relays: Applications and Design Considerations
- Typical operating conditions. They can be part of guard monitoring or emergency-stop circuits designed to the required architecture. For this use, specify control signal, load waveform, switching frequency and the required state when control power is removed. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for 1003100 gives coil voltage as 24VAC/DC, contact form as SPST-NO (1 Form A) x 2, contact rating (current) as 2:00 AM. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for 1003157 gives termination style as Screw Terminal, operate time as 10 ms, release time as 10 ms. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Check the load type used for the published rating. A resistive load, an inductive load and a capacitive input impose different stresses during switching. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the safety relays check, check the exact device certification, contact arrangement and monitoring requirements against the system design. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for Safety Relays
- Define the acceptance criteria. Check the exact device certification, contact arrangement and monitoring requirements against the system design. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include mounting type, coil voltage, contact form, contact rating (current). Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for 1003157 gives contact form as SPST-NO (1 Form A) x 2, contact rating (current) as 2:00 AM, termination style as Screw Terminal. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. Read the notes attached to any rating used in your decision. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required safety relays by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the switching assembly, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.