D3C2021-5View Product
RF Circulators and Isolators
RF Circulators and RF Isolators are passive devices that guide and suppress radio frequency. These are used to protect receiver circuitry. These are filtered by type, frequency range, isolation, connector type, and more.
RF Circulators And Isolators: Features and Specifications
- Function in the design. A circulator routes power between ports in a preferred direction, while an isolator attenuates reverse power. Start with the role the component plays in the RF signal path. Check frequency band, isolation, insertion loss and power rating. An RF antenna couples energy between a feed line and free space. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- AM150-160CIR107 at a glance. The listing for AM150-160CIR107 gives type as Circulator, frequency as 150 MHz ~ 160 MHz, isolation as 20dB (Min). These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For type, AM150-160CIR107 is listed as Circulator and AM2000-4000IS126 as Isolator. When comparing rf circulators and isolators, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
RF Circulator: Applications and Design Considerations
- Typical operating conditions. They separate transmit and receive paths or protect RF sources from reflections. For this use, specify operating band, port impedance, signal level and loss in cables or board traces. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for AM2000-4000IS126 gives frequency as 2 GHz ~ 4 GHz, isolation as 20dB (Min), power - average forward as 1 W. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for AM1300-1530CIR1119 gives insertion loss as 0.5dB (Max), vswr as 1.25, package / case as Module. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Define the measurement reference plane. A result that includes cable and connector loss cannot be compared directly with a specification at the device ports. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the rf circulators and isolators check, check frequency band, isolation, insertion loss and power rating. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for RF Isolator
- Define the acceptance criteria. Check frequency band, isolation, insertion loss and power rating. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include type, frequency, isolation, power - average forward. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for AM1300-1530CIR1119 gives isolation as 20dB (Min), power - average forward as 50 W, insertion loss as 0.5dB (Max). Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For package / case, the respective entries for AM2000-4000IS126 and AM1300-1530CIR1119 are Module, SMA Connectors and Module. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required rf circulators and isolators by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the RF signal path, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
ChipApex | Global Electronic Components Supplier