Brand

Product categories

Filters

Electronic Filters

The filter product category includes a wide variety of devices and materials used for the separation, suppression, or selection of electrical and magnetic signals based on frequency. Products designed for use across a wide range of contexts including CM chokes and EMI/RFI filters for example. Ranging from power lines carrying kiloamperes at DC to radio receivers detecting microvolt-level signals at frequencies of tens of gigahertz.

Screen Default Ranking Price By Date

Electronic Filters: Features and Specifications

  • Function in the design. An electronic filter passes some frequencies and attenuates others. Start with the role the component plays in the signal path. Identify the passband and stopband before comparing insertion loss and termination impedance. A ceramic filter uses frequency-dependent behavior to select or attenuate part of an electrical signal. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
  • 104M06QC100 at a glance. The listing for 104M06QC100 gives type as Low Pass, filter order as 1st, technology as RC. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
  • Differences within the range. For resistance - channel (ohms), 104M06QC100 is listed as 100 and 104M06QC150 as 150. When comparing filters, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.

Electrical Filter: Applications and Design Considerations

  • Typical operating conditions. Filters separate wanted signals from interference in power feeds, radio paths and instrumentation. For this use, specify wanted bandwidth, unwanted frequency components and the impedances on either side of the filter. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
  • Integration example. The listing for 104M06QC150 gives filter order as 1st, technology as RC, number of channels as 1. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for AMI-21-1-1 gives frequency - operating as DC ~ 400Hz, approval agency as CE, cURus, operating temperature as -25°C ~ 100°C. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
  • Checks on the prototype. Compare the response with the intended source and load. A laboratory insertion loss curve depends on the fixture and its termination. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the filters check, identify the passband and stopband before comparing insertion loss and termination impedance. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.

Selection Criteria for Electronic Filters

  • Define the acceptance criteria. Identify the passband and stopband before comparing insertion loss and termination impedance. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include type, filter order, technology, number of channels. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
  • Compare exact ordering codes. The listing for AMI-21-1-1 gives voltage - rated ac as 250V, current as 1:00 AM, frequency - operating as DC ~ 400Hz. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For mounting type, the respective entries for 104M06QC150 and AMI-21-1-1 are Through Hole and Chassis Mount. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
  • Prepare the purchase specification. For a quotation, identify the required filters by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the signal path, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
Add ComparisonUp to 4 can be added

    Recommended Products

    Recent News